Effectiveness of XP-Endo Finisher in the reduction of bacterial load in oval-shaped root canals

Abstract: This study investigated the effectiveness of XP-Endo Finisher (XPF) associated with XP-Endo Shaper (XPS) or Reciproc Blue (RB) files in reducing bacterial load in oval-shaped root canals (RC) during chemomechanical preparation (CMP) using 0.9% saline solution (NaCl) or 2.5% sodium hypochlorite (NaOCl). Eighty mandibular incisors with single oval-shaped RC were contaminated with Enterococcus faecalis. The teeth were randomly assigned to eight experimental groups (n = 10) according to the CMP, as follows: G1: XP… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
32
0
11

Year Published

2019
2019
2023
2023

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 41 publications
(49 citation statements)
references
References 33 publications
(49 reference statements)
6
32
0
11
Order By: Relevance
“…2012, Carvalho et al . 2019). From S2 to S3, there was also a significant reduction in microbial load in all groups ( P < 0.05).…”
Section: Discussionmentioning
confidence: 99%
“…2012, Carvalho et al . 2019). From S2 to S3, there was also a significant reduction in microbial load in all groups ( P < 0.05).…”
Section: Discussionmentioning
confidence: 99%
“…15,16 Various in vitro studies claimed that XP-endo Shaper induces minimal stress on dentinal walls, thereby preventing formation of new dentinal cracks and also effective in reducing microbial count levels in oval shaped canals. [17][18][19][20][21][22][23] However, there is lack of clinical studies to prove the effectiveness of three-dimensional rotary systems over traditional files. A recent systematic review of clinical trials (Siddique and Nivedhitha, 2019) demonstrated that there was no significant difference between rotary as well as reciproc system on microbial reduction.…”
Section: Introductionmentioning
confidence: 99%
“…Observando que o valor médio da distância vestíbulolingual dos canais ovais longo a 6mm do ápice radicular é de 1,04 mm (Tabela 2), nenhum instrumento do sistema Reciproc Blue ® seria capaz de tocar em todas as paredes, tendo em vista que a essa o distância (D6) o instrumento R25 possui é de 0,73 mm, o R40 0,76 mm e o R50 0,80 mm. Tal fato se reveste é de grande implicação clínica para a rotina endodôntica, uma vez que paredes não tocadas são locais propensos a presença ou persistência de microrganismos (Carvalho, et al, 2019). Ao preparar os canais classificados como ovais, ovais longos ou achatados, o operador deve se alertar para uma instrumentação mais crítica, reduzindo as possibilidades de preparo incompleto do canal radicular principal.…”
Section: Discussionunclassified