2016
DOI: 10.17925/eor.2016.10.02.94
|View full text |Cite
|
Sign up to set email alerts
|

Effective Ocular Biometry and Intraocular Lens Power Calculation

Abstract: Since the introduction of phacoemulsification, cataract surgery has evolved remarkably. The use of premium intraocular lenses (IOLs) (aspheric, toric, multifocal), refractive lens exchange and patients after refractive surgery procedures require extremely precise clinical measurements and IOL calculation formulas to achieve desired postoperative refraction. For many years, ultrasound biometry has been the standard for measurement of ocular parameters. The introduction of optical biometry (fast and non-invasive… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0
4

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(25 citation statements)
references
References 0 publications
0
21
0
4
Order By: Relevance
“…Nejnovější technologií pro měření optické biometrie je tzv. swept source OCT (ss-OCT), kterou využívá IOLMaster 700 (Carl Zeiss Meditec, Jena, Německo) a ARGOS (Movu, Santa Clara, Kalifornie, USA) [5]. Přístroje pro optickou biometrii obsahují software, který dosadí změřené hodnoty do vzorců pro výpočet dioptrické hodnoty PC IOL.…”
Section: úVodunclassified
“…Nejnovější technologií pro měření optické biometrie je tzv. swept source OCT (ss-OCT), kterou využívá IOLMaster 700 (Carl Zeiss Meditec, Jena, Německo) a ARGOS (Movu, Santa Clara, Kalifornie, USA) [5]. Přístroje pro optickou biometrii obsahují software, který dosadí změřené hodnoty do vzorců pro výpočet dioptrické hodnoty PC IOL.…”
Section: úVodunclassified
“…These results are also in agreement with other studies comparing both methods of IOL power calculation. [17][18][19] The process of ocular biometry has become simplified with IOL master. Since IOL master is noncontact technique, so topical anesthesia is not required.…”
Section: Discussionmentioning
confidence: 99%
“…The study was started after taking approval from hospital ethics committee (201/ERC/AFIO dated 29- [11][12][13][14][15][16][17][18][19]. In this cross-sectional comparative study, a total of 70 patients visiting cataract clinic of Armed Forces Institute of Ophthalmology for cataract surgery were included, from June to December 2018.…”
Section: Methodsmentioning
confidence: 99%
“…Optimal refractive outcomes can be achieved by employing good surgical technique, aiming for a low rate of posterior capsular rupture, having a capsulorhexis size smaller than the optical diameter, and having an in-the-bag IOL placement [ 2 ]. Continuous curvilinear capsulorhexis ensures positional stability and enhances refractive predictability [ 2 , 25 ], while small incisions without sutures and the use of foldable IOLs reduce the incidence of complications and surgically induced astigmatism (SIA) [ 51 ], and complete ophthalmic viscosurgical device removal reduces the likelihood of IOL misalignment [ 52 ]. Non-intentional SIA can be prevented by pre-operative assessment of corneal hysteresis and biomechanical properties of the cornea, followed by microincision surgery using corneal topography data and standard IOL power formulae [ 3 ].…”
Section: Pre- Intra- and Post-operative Factors That Affect Refractiv...mentioning
confidence: 99%