2013 IEEE Global Humanitarian Technology Conference: South Asia Satellite (GHTC-SAS) 2013
DOI: 10.1109/ghtc-sas.2013.6629916
|View full text |Cite
|
Sign up to set email alerts
|

Effect of vertical wind shear on flicker in wind farm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
0
2

Year Published

2014
2014
2023
2023

Publication Types

Select...
3
3
1

Relationship

2
5

Authors

Journals

citations
Cited by 35 publications
(5 citation statements)
references
References 5 publications
0
3
0
2
Order By: Relevance
“…Cuando la penetración de la energía eólica es alta, el control de voltaje en el sistema de distribución se vuelve particularmente importante (Chavan, 2013). En muchos países, los nuevos códigos de red establecidos exigen que los parques eólicos incorporen generadores de inducción doblemente alimentados (DFIG) para que participar activamente en la mejora de control de voltaje en el sistema de distribución (Zhao et al, 2010).…”
Section: Transitoriosunclassified
See 1 more Smart Citation
“…Cuando la penetración de la energía eólica es alta, el control de voltaje en el sistema de distribución se vuelve particularmente importante (Chavan, 2013). En muchos países, los nuevos códigos de red establecidos exigen que los parques eólicos incorporen generadores de inducción doblemente alimentados (DFIG) para que participar activamente en la mejora de control de voltaje en el sistema de distribución (Zhao et al, 2010).…”
Section: Transitoriosunclassified
“…La estandarización de los flicker fue realizada por la Comisión Electrotécnica Internacional (IEC) descrita en la norma IEC 61000-4-15 (Ignacio, 2010), (Chavan, 2013).…”
Section: Flickerunclassified
“…When the generator is driven by the undulatory torque, the shaft speed and rotor speed of permanent magnet synchronous generator (PMSG) would be periodically fluctuating at 3p frequency as well [6]. Such forced fluctuation of wind turbine torque under wind shear would cause a series of power quality issues [7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…The results are achieved in a laboratory wind tunnel with small models of hills with different slopes and wind turbine. Chavan et al [10] have introduced WS (in addition to wind speed and grid impedance phase angle) as an extra parameter for computing the emission of flicker in wind turbine which is installed in a village in India. The effect of WS on flicker emission in different types of terrains such as different types of hills [11] and vegetation of riverside [12] has been studied experimentally in wind turbines.…”
Section: Introductionmentioning
confidence: 99%
“…There are some mechanical factors which cause flicker in wind turbines. These faults are not modelled in [4–12]. Simulation results have shown that these faults are more important than WS and TS and cause worst effects on output power specially flicker.…”
Section: Introductionmentioning
confidence: 99%