2008
DOI: 10.1016/j.jfluidstructs.2007.06.004
|View full text |Cite
|
Sign up to set email alerts
|

Effect of ventricle motion on the dynamic behaviour of chorded mitral valves

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

5
42
1

Year Published

2008
2008
2017
2017

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 32 publications
(50 citation statements)
references
References 40 publications
5
42
1
Order By: Relevance
“…The fluid-structure interaction between mitral leaflets and the surrounding blood was taken into account by Einstein et al (2005a) and Watton et al (2007Watton et al ( , 2008. The two groups modelled the fluid-structure coupling through different algorithms:…”
Section: (D ) Valve-blood Interactionmentioning
confidence: 99%
See 1 more Smart Citation
“…The fluid-structure interaction between mitral leaflets and the surrounding blood was taken into account by Einstein et al (2005a) and Watton et al (2007Watton et al ( , 2008. The two groups modelled the fluid-structure coupling through different algorithms:…”
Section: (D ) Valve-blood Interactionmentioning
confidence: 99%
“…This second clinical issue was also the subject of the study of Dal Pan et al (2005). Very recently, a sixth research group has used fluid-structure interaction modelling as a tool to predict the performance of bioprosthetic mitral valves (Watton et al 2007(Watton et al , 2008. Although the focus of their studies is on prostheses with different morphological and mechanical properties when compared with the natural human valve, their modelling strategy could be adopted in analysis of the mitral valve.…”
Section: Introductionmentioning
confidence: 99%
“…Let V * (t) be the volume of blood in the ventricle during the heart cycle, with a maximum V 274 V. Meschini, M. D. de Tullio, G. Querzoli and R. Verzicco & Tonti (2010) and Querzoli et al (2010) have underlined the strong influence the mitral valve has on the diastolic flow structure, and Einstein et al (2005), Wattona et al (2008) and Griffith et al (2009) have focused on the dynamics of mitral valve leaflets. Moreover, McQueen & Peskin (2000) and Mihalef et al (2011) have studied the effect of combining realistic intra-ventricular flow with a physiological mitral valve using patient-specific models without fluid-structure interaction.…”
mentioning
confidence: 99%
“…Over the last few years there have been a number of FSI valvular models using the immersed boundary (IB) approach [6,7,13,18]. However, none of these MV models included the effect of the LV motion, hence the flow field is not physiological.…”
Section: Introductionmentioning
confidence: 99%