2018
DOI: 10.1016/j.buildenv.2018.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Effect of the suspended ceiling with low-frequency resonant panel absorber on heavyweight floor impact sound in the building

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
3
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 20 publications
(6 citation statements)
references
References 22 publications
0
3
0
Order By: Relevance
“…Thus, an investigation on this topic is of paramount importance. Indeed, some previous research has focused on the analysis of the impact noise produced by a rubber ball on concrete floors [49][50][51][52][53] but only a few studies have focused on timber floors [54][55][56][57] and these have not been very comprehensive. Furthermore, a comparison of the three sound sources (dodecahedron, tapping machine and rubber ball) is missing in the literature.…”
Section: Research Gapmentioning
confidence: 99%
“…Thus, an investigation on this topic is of paramount importance. Indeed, some previous research has focused on the analysis of the impact noise produced by a rubber ball on concrete floors [49][50][51][52][53] but only a few studies have focused on timber floors [54][55][56][57] and these have not been very comprehensive. Furthermore, a comparison of the three sound sources (dodecahedron, tapping machine and rubber ball) is missing in the literature.…”
Section: Research Gapmentioning
confidence: 99%
“…The progress of developing ceiling structures in receiving rooms to reduce noise from floor impacts is also underway [21][22][23][24][25][26]. This involves using internal acoustic materials to minimize the amplification of impact noises to the room below due to the influence of the air layer within the ceiling and a ceiling-less design to minimize the transmission of impact noises through the ceiling.…”
Section: Introductionmentioning
confidence: 99%
“…Especially, approaches with resilient layers in-between concrete slab and screed are the most popular method directly to reduce floor impact noises [14][15][16]. However, there are limitations to improve reducing the performance of impact noises only with floor treatment under a floating floor system with a limited total thickness (about 110 mm including resilient materials, leveling light-weight concrete, and finishing mortar) [17][18][19]. Therefore, it is needed for both new construction and remodeling purposes to develop additional architectural treatments such as ceiling and wall finishes in receiving rooms except for floor structure [20].…”
Section: Introductionmentioning
confidence: 99%