2012
DOI: 10.1016/j.jct.2012.03.024
|View full text |Cite
|
Sign up to set email alerts
|

Effect of temperature on the physical properties of 1-butyl-3-methylimidazolium based ionic liquids with thiocyanate and tetrafluoroborate anions, and 1-hexyl-3-methylimidazolium with tetrafluoroborate and hexafluorophosphate anions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
70
2
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 111 publications
(79 citation statements)
references
References 31 publications
6
70
2
1
Order By: Relevance
“…The average relative deviations between the data collected in this work and those already reported [41][42][43][44][45][46][47][48][49] are depicted in Figure 2. The absolute average relative deviations between the data collected in this work and those reported in the literature are 2.…”
Section: Surface Tensionmentioning
confidence: 70%
See 2 more Smart Citations
“…The average relative deviations between the data collected in this work and those already reported [41][42][43][44][45][46][47][48][49] are depicted in Figure 2. The absolute average relative deviations between the data collected in this work and those reported in the literature are 2.…”
Section: Surface Tensionmentioning
confidence: 70%
“…The surface tension of the ILs investigated was determined at atmospheric pressure in the temperature range from (298.15 to 343.15) K. Surface tension data for imidazolium-based ILs with anions functionalized with cyano groups present considerable discrepancies among different authors [41][42][43][44][45][46][47][48][49]. The average relative deviations between the data collected in this work and those already reported [41][42][43][44][45][46][47][48][49] are depicted in Figure 2.…”
Section: Surface Tensionmentioning
confidence: 81%
See 1 more Smart Citation
“…All the ILs show complete miscibility with methanol in the whole composition ranges. Densities of pure [C 4 C 1 im][SCN] were compared with the reported values [32,33]. The maximum discrepancies between our measurement and those reported by Sanchez et al [32] and Vakili-Nezhaad et al [33] are 0.015 and 0.028%, respectively.…”
Section: Densitymentioning
confidence: 38%
“…The effect of temperature and pressure in SILMs performance has been often investigated in the literature [5,[68][69][70][71]. Cserjesi et al investigated the dependence of temperature and pressure on gas permeation and determined the permeability, selectivity, and stability of SILMs prepared with novel, VACEM-type ionic liquids [72].…”
Section: Effects Of Temperature and Pressure In Silms Performancementioning
confidence: 99%