1998
DOI: 10.1016/s0021-9673(98)00835-8
|View full text |Cite
|
Sign up to set email alerts
|

Effect of temperature on retention of enantiomers of β-methyl amino acids on a teicoplanin chiral stationary phase

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
43
0
3

Year Published

2000
2000
2014
2014

Publication Types

Select...
9
1

Relationship

4
6

Authors

Journals

citations
Cited by 130 publications
(48 citation statements)
references
References 47 publications
2
43
0
3
Order By: Relevance
“…CHIROBIOTIC TAG is one of the most appropriate columns to analyse amino acids with a hyphenated system HPLC-MS and without any previous derivatisation because it permits to separate optical isomers using volatile mobile phase with a high percentage of organic solvent, preserving the spray stability [38,47,48].…”
Section: Chromatographic Separationmentioning
confidence: 99%
“…CHIROBIOTIC TAG is one of the most appropriate columns to analyse amino acids with a hyphenated system HPLC-MS and without any previous derivatisation because it permits to separate optical isomers using volatile mobile phase with a high percentage of organic solvent, preserving the spray stability [38,47,48].…”
Section: Chromatographic Separationmentioning
confidence: 99%
“…No or only partial separation was achieved for aMe-substituted unusual amino acids (with the exception of a-methyl-1,2,3,4-tetrahydroisoquinoline-3-carboxylic acid (a-MeTic-3) [70,72] and for alicyclic b-amino acids [70]. Nice separations were attained for the b-substituteda-amino acid diastereomers (four enantiomers) of bMePhe, b-MeTyr, b-MeTic-3 and b-MeTrp [71], for different b-alkyl or aryl-substituted Trp analogs [73] and for the enantioseparation of Ala, Phe [74] and secondary amino acid analogs [75]. N-t-Boc protection in most cases decreased the quality of resolution relative to that for the nonprotected amino acid analogs [74].…”
Section: Enantioseparation Of Nonprotected Protein and Unusual Amino mentioning
confidence: 99%
“…The HPLC measurements were carried out on a Waters HPLC system consisting of an M-600 low-pressure gradient pump, an M-996 photodiode-array detector, and a Millenium 32 Chromatography Manager data system; the alternative Waters Breeze system consisted of a 1525 binary pump, a 487 dual-channel absorbance detector, a 717 plus autosampler, and Breeze data manager software (both systems from Waters Chromatography, Milford, MA). Both chromatographic systems were equipped with Rheodyne Model 7125 injectors (Cotati, CA) with 20-ll loops.…”
Section: Apparatus and Chromatographymentioning
confidence: 99%