2008
DOI: 10.1016/j.renene.2007.01.005
|View full text |Cite
|
Sign up to set email alerts
|

Effect of solar radiation correlations on system sizing: PV pumping case

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(6 citation statements)
references
References 17 publications
0
6
0
Order By: Relevance
“…Considering papers which address the development and application of models and methods for the simulation and sizing of off-grid systems, it can be noticed that major attention has been devoted to hybrid micro-grid systems [134,137,139, and stand-alone [105,113,117,[184][185][186][187][188][189][190][191][192][193][194][195][196][197], while a small number of papers focuses on micro-grid [198][199][200][201][202]. A complete synthesis of all the selected papers is given in Appendix C, Tables C.1-C.3.…”
Section: Models and Methods For Simulation And Sizingmentioning
confidence: 99%
See 1 more Smart Citation
“…Considering papers which address the development and application of models and methods for the simulation and sizing of off-grid systems, it can be noticed that major attention has been devoted to hybrid micro-grid systems [134,137,139, and stand-alone [105,113,117,[184][185][186][187][188][189][190][191][192][193][194][195][196][197], while a small number of papers focuses on micro-grid [198][199][200][201][202]. A complete synthesis of all the selected papers is given in Appendix C, Tables C.1-C.3.…”
Section: Models and Methods For Simulation And Sizingmentioning
confidence: 99%
“…Description 1 [184] India Wn -Modeling and simulation of wind-driven roto-dynamic pumps to compute instantaneous and integrated performances 2 [185] Bangladesh PV, B 0.3 Intuitive sizing technique for PV-battery systems 3 [105,[186][187][188] Sahara PV -Optimal operation and sizing of PV pumping systems with optimization of the induction motor efficiency 4 [189] Algeria PV -Model for current-voltage curves of PV modules and loss of load probability computation for PV pumping systems 5 [190] PV, D, B Development of sizing curves for PV-battery and diesel-battery systems via simulations 6 [191] Turkey PV 3 Analyses of power output errors due to use of solar radiation correlations in PV pumping sizing 7 [192,196] Iran Wn 85-90 Simulation and sizing of wind turbine considering instantaneous wind speed variationsmodeling of novel voltage and frequency controller 8 [193][194][195] Algeria, Nigeria PV 20 kW Numerical sizing and Particle Swarm optimization techniques for solar pumping systems with storage 9 [113] Malaysia H 2.85 Matlab-Simulink model for simulation of real PHP plant in university campus 10 [117] Iraq PV, B 3 Visual Basic tool to design PV-battery systems based on an intuitive sizing technique 11 [197] Tunisia PV, B 13 Fuzzy logic control (modeling and analysis) for off-grid PV systems considering variable load Note: PV (photovoltaic), Wn (wind), H (hydro), B (battery), D (diesel).…”
Section: N Publication Location Technology Size Range [Kw]mentioning
confidence: 99%
“…Therefore, they are more preferred than non-renewable energy sources [10]. Considering some values related to solar radiation intensity, the variation of the amount of power obtained from the PV water pumping system is investigated [11]. The size, life cycle, and cost of a system that can pump an average of 60 m 3 of water per day in Algeria have been analyzed.…”
Section: Introductionmentioning
confidence: 99%
“…Some of the investigations are reported in the literature on these issues. Researchers [27][28][29][30][31][32] investigated the effect of optimum size of PV array configuration, Series×Parallel (S×P), to maximize the delivered water at given location and head. They reported that optimum PV array configuration affects the optimum quantity of water required for the worst month, energy requirement of the loads, radiation intensity level and location and water consumption profile of the site.…”
Section: Introductionmentioning
confidence: 99%