1990
DOI: 10.1016/0301-5629(90)90147-5
|View full text |Cite
|
Sign up to set email alerts
|

Effect of scan format on refraction artifacts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

1991
1991
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(18 citation statements)
references
References 14 publications
0
18
0
Order By: Relevance
“…The geometric distortion of ultrasound images of circular objects has been examined previously [6,7], including by ray models [5,4]. Our analysis extends this previous body of work by quantifying the distortion of area, and thereby providing new insight into the errors in the ultrasonic evaluation of area and volume of anatomical features.…”
Section: Discussionmentioning
confidence: 61%
“…The geometric distortion of ultrasound images of circular objects has been examined previously [6,7], including by ray models [5,4]. Our analysis extends this previous body of work by quantifying the distortion of area, and thereby providing new insight into the errors in the ultrasonic evaluation of area and volume of anatomical features.…”
Section: Discussionmentioning
confidence: 61%
“…They encompass a wide range of US signs and phenomena, including (amongst others) lateral shadowing, the flag sign (signe du drapeau), duplication artifacts, revolving door-like posttumoral distorted vascular images, and the raindrop phenomenon in alcoholic liver cirrhosis. [1][2][3][4][5][6][7][8][9]29 With B-mode imaging, the location of the target is determined by the time taken for the reflective echo of the target to reach the transducer. Usually, there is a simple correspondence between the displayed location on the US image and the actual location of the target.…”
Section: Resultsmentioning
confidence: 99%
“…[1][2][3][4][5][6][7][8][9] However, these investigations have concerned two-dimensional (2-D) US images only, and the whole structure of refractive artifacts is not well understood.…”
Section: Introductionmentioning
confidence: 99%
“…Using a computer model and confirming the results with an ultrasound phantom, sector transducers had more prominent retrolenticular afterglow which was accentuated when the rounded structure moved towards the transducer . 21 This effect was not observed with linear array transducers.…”
Section: Acoustic Reflection Andmentioning
confidence: 95%