2017
DOI: 10.1016/j.compositesb.2016.09.054
|View full text |Cite
|
Sign up to set email alerts
|

Effect of reinforcement ratio on the flexural performance of hybrid FRP reinforced concrete beams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
79
1
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 151 publications
(83 citation statements)
references
References 26 publications
2
79
1
1
Order By: Relevance
“…To predict the structural behaviour of FRP bonded in a macroscale manner, the interfacial parameters generated by MD simulation can be converted into finite element simulation using cohesive zone model (CZM), which is widely used in simulating the fracture process in polymers, metals and composites [116][117][118]. CZM was first introduced as a technique to study the fracture in quasi-brittle materials such as ceramic and concrete.…”
Section: Macroscale Model Using Finite Element Methodsmentioning
confidence: 99%
“…To predict the structural behaviour of FRP bonded in a macroscale manner, the interfacial parameters generated by MD simulation can be converted into finite element simulation using cohesive zone model (CZM), which is widely used in simulating the fracture process in polymers, metals and composites [116][117][118]. CZM was first introduced as a technique to study the fracture in quasi-brittle materials such as ceramic and concrete.…”
Section: Macroscale Model Using Finite Element Methodsmentioning
confidence: 99%
“…In other words, the compatibility between the modelling used in this study and the test results of static push-over tests conducted by Cho et al (2012), for general studs, has already been examined. Many studies based on numerical analyses using computers (Duarte et al, 2016;Kim et al, 2016;Lim et al, 2016;Ozcelik and Clayton, 2017;Qin et al, 2017;Ren et al, 2015) have been carried out. The professional FEA program Abaqus, which reasonably analyses the non-linear behaviour of SC shear walls, was utilised in the current study.…”
Section: Finite-element Analyses Of Sc Shear Wallsmentioning
confidence: 99%
“…Therefore, serviceability limit state is generally controlling the design of FRP reinforced concrete structures [6][7][8][9][10][11][12] . Hybrid reinforced concrete structures [21][22][23][24][25][26][27][28] , where FRP reinforcement located closer to the external environment and steel bars embedded in concrete with largest possible cover, combine the advantage of ductility and durability of steel or FRP reinforced concrete structures.…”
Section: Introductionmentioning
confidence: 99%