2020
DOI: 10.1016/j.measurement.2019.107074
|View full text |Cite
|
Sign up to set email alerts
|

Effect of position of temperature sensors on the resulting volumetric accuracy of the machine tool

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 15 publications
0
5
0
1
Order By: Relevance
“…It is necessary to monitor the surrounding environment throughout the measurement process. Monitoring was carried out according to the procedure described in [20].…”
Section: The Strategy Of the Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…It is necessary to monitor the surrounding environment throughout the measurement process. Monitoring was carried out according to the procedure described in [20].…”
Section: The Strategy Of the Experimentsmentioning
confidence: 99%
“…It is necessary to monitor the surrounding environment throughout the measurement process. Monitoring was carried out according to the procedure described in [20]. In both parts of the experiment, circular interpolation measurements were performed with the Ballbar QC20-w, RENISHAW (DBB) for machining without DBB1 compensations and for machining with DBB2 volumetric compensations, according to ISO 230-4 [31].…”
Section: The Strategy Of the Experimentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, devices such as multiple beam interferometers are described in [Holub 2019A]. The main focus of publications [Schwenke 2009] and [Holub 2017] is to find a way how to implement the volumetric compensations as quickly as possible, Furthermore, it is necessary to have access to the machine to appropriately set up monitoring of the ambient conditions of the machine in order to minimize measurement uncertainty in terms of results [Holub 2019B]. It is the elimination of internal and external negative effects that plays an important role in the implementation of volumetric compensations and their resulting impact.…”
Section: Introductionmentioning
confidence: 99%
“…O autor sugere o fato da temperatura do ambiente ter sido medida fora da carenagem da MF como um dos fatores da baixa previsibilidade do erro térmico. De forma similar, Holub et al (2019) argumenta que é melhor medir a temperatura dentro da carenagem da máquina, de preferência próximo aos atuadores dos eixos.…”
Section: Convecção No Modelo Estruturalunclassified