2021
DOI: 10.1016/j.theriogenology.2021.05.021
|View full text |Cite
|
Sign up to set email alerts
|

Effect of melatonin supplementation during IVM of dromedary camel oocytes (Camelus dromedarius) on their maturation, fertilization, and developmental rates in vitro

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 23 publications
(17 citation statements)
references
References 45 publications
0
17
0
Order By: Relevance
“…Assessment of TAC was done using commercial kits (total antioxidant capacity, Bio-diagnostic, Dokki, Egypt) spectrophotometrically at a wavelength of 505 nm, based on a previous study ( 38 ). The assay rationale is the measurement of the suppressive ability of the sample on sodium benzoate conversion to thiobarbituric acid substances via reactive oxygen species (ROS) generated from Fenton's reaction ( 39 ).…”
Section: Methodsmentioning
confidence: 99%
“…Assessment of TAC was done using commercial kits (total antioxidant capacity, Bio-diagnostic, Dokki, Egypt) spectrophotometrically at a wavelength of 505 nm, based on a previous study ( 38 ). The assay rationale is the measurement of the suppressive ability of the sample on sodium benzoate conversion to thiobarbituric acid substances via reactive oxygen species (ROS) generated from Fenton's reaction ( 39 ).…”
Section: Methodsmentioning
confidence: 99%
“…The measurement of TAC is based on the ability of a sample's antioxidant content to suppress an exogenously supplemented H 2 O 2 (with a defined amount), and the residual H 2 O 2 is estimated via its ability to convert 3,5, dichloro −2– hydroxy benzenesulfonate to a coloured product. Practically, TAC levels were assessed photometrically using commercial kits (Total Antioxidant Capacity Kit, Bio‐diagnostics, Egypt) via a spectrophotometer adjusted at 505 nm wavelength following the manufacturer's instruction with an intra‐assay CV of 3.4% and a least detectable concentration of 0.04 mmol/L (Fathi et al, 2021).…”
Section: Methodsmentioning
confidence: 99%
“…To exclude the inter-assay variations, all the biochemical evaluations (W0-W8) were performed on the same day after the end of the study. Colormetrically using a spectrophotometer, commercial research kits were used for assaying the levels and activities of TAC (mM/L), CAT (U/L), MDA (mM/mL) (Biodiagnostics, Dokki, Giza, Egypt), and ALT (U/ml; Spectrum-diagnostic, Obour city, Cairo, Egypt) specifically at 510, 520, 534, and 505 nm wavelengths, respectively, following the manufacturer’s instructions (Fathi et al 2021 ).…”
Section: Methodsmentioning
confidence: 99%