2009
DOI: 10.1007/s10694-009-0091-y
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Heating and Cooling on Axially Restrained RC Columns with Special-Shaped Cross Section

Abstract: This paper describes the performance of 12 axially restrained RC columns (four for each type of cross section, i.e., +-, T-and L-shaped cross section) under fire conditions that were recently finished in South China University of Technology. The main objective of the paper is to investigate the effect of axial restraint on RC columns during both expanding and contracting phases. The RC columns were all initially concentrically loaded and subjected to ISO834 standard fire on all sides. Axial restraints were imp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 23 publications
(24 reference statements)
0
7
0
Order By: Relevance
“…It should be noted that no creep is explicitly considered in these relationships for steel reinforcement, which is an important assumption as the creep of the steel reinforcement is known to have an effect on stress and strain state in reinforced concrete frames when temperature in reinforcement bars exceeds 400°C [21,22], as is the case here. The axial restraint stiffness remains unchanged during the simulations, which can be justified by the fact that the maximum displacement at the center of the restraining beam is only about 13 mm [14]. The deformation behavior and the evolution of the axial load for the eight experiments can be observed in Figure 6.…”
mentioning
confidence: 88%
See 3 more Smart Citations
“…It should be noted that no creep is explicitly considered in these relationships for steel reinforcement, which is an important assumption as the creep of the steel reinforcement is known to have an effect on stress and strain state in reinforced concrete frames when temperature in reinforcement bars exceeds 400°C [21,22], as is the case here. The axial restraint stiffness remains unchanged during the simulations, which can be justified by the fact that the maximum displacement at the center of the restraining beam is only about 13 mm [14]. The deformation behavior and the evolution of the axial load for the eight experiments can be observed in Figure 6.…”
mentioning
confidence: 88%
“…Implicit models such as the EC2 model have limitations that, even though they were not considered as significant when following a prescriptive design, could lead to inappropriate results when a performance-based design including the cooling phase is performed. To highlight the difference in the structural response obtained using implicit or explicit models, a series of experimental fire tests performed at South China University of Technology [14] has been numerically modeled using the nonlinear software SAFIR [15]. Two different concrete models were used for comparison: on the one hand, the current EC2 model, and on the other hand, a new formulation of the EC2 model that contains an explicit term for transient creep strain.…”
Section: Objectives Of the Studymentioning
confidence: 99%
See 2 more Smart Citations
“…In the past decade, research has been concentrated on the fire performance of normal RC columns (Al-Salloum et al, 2016; Hwang et al, 2016; Raut and Kodur, 2011; Wu et al, 2010) or steel and composite columns (Abbas et al, 2017; Espinos et al, 2014; Won et al, 2016). In contrast, the research studies on the fire performance of specially shaped columns are limited.…”
Section: Introductionmentioning
confidence: 99%