2009
DOI: 10.1111/j.1751-553x.2008.01094.x
|View full text |Cite
|
Sign up to set email alerts
|

Effect of HbS in the determination of HbA2 with the Menarini HA‐8160 analyzer and comparison with other instruments

Abstract: It is known that the presence of hemoglobin S (HbS) affects the determination of hemoglobin A(2) (HbA(2)) levels in clinical samples. We quantitated this effect using the Menarini HA-8160 analyzer and compared with other instruments (HELENA beta-thal quik column, TOSOH HLC-723G7 and BIORAD Variant II) using the HELENA SAS-MX alkaline gel electrophoresis kit as the reference method. The %HbA(2) values from the HA-8160 analyzer and the alkaline gel electrophoresis show a good linear correlation in the absence of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
6
0
2

Year Published

2011
2011
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 11 publications
3
6
0
2
Order By: Relevance
“…With regard to the imprecision, the data obtained in our study proven that all methods were performing better than 4.5% CV, as also recently reported (Anagnostopoulos et al. , 2009), thus confirming that the quality of the automated HPLC and CE methods is higher with respect to the imprecision obtainable years ago with the minicolumns methods (Brosius et al.…”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…With regard to the imprecision, the data obtained in our study proven that all methods were performing better than 4.5% CV, as also recently reported (Anagnostopoulos et al. , 2009), thus confirming that the quality of the automated HPLC and CE methods is higher with respect to the imprecision obtainable years ago with the minicolumns methods (Brosius et al.…”
Section: Discussionsupporting
confidence: 91%
“…With regard to the imprecision, the data obtained in our study proven that all methods were performing better than 4.5% CV, as also recently reported (Anagnostopoulos et al, 2009), thus confirming that the quality of the automated HPLC and CE methods is higher with respect to the imprecision obtainable years ago with the minicolumns methods (Brosius et al, 1978), or by cellulose acetate electrophoresis followed by densitometry, or after elution of the HbA and HbA 2 bands and spectrophotometric quantitation (International Committee for Standardization in Haemathology 1978). However, from a recent study we have performed under rigorous conditions in agreement with the approach recommended (Fraser & Harris, 1989), HbA 2 seems to have a very narrow intra-individual biological variability, of the order of 0.4% (as CV), as for a typical genetic marker (Paleari et al, 2011).…”
Section: Discussionsupporting
confidence: 89%
“…A strong positive bias in the HbA 2 values from the ADAMS ™ A1C HA‐8160 T is apparent in the presence of HbS ; this spurious increment was not found in the new analyzer.…”
Section: Discussionmentioning
confidence: 79%
“…Hemoglobin varyantlarının tanısı için kullanılan yöntemler tarama testleri ve kesin tanı yöntemleri olarak ikiye ayrılır. Hemoglobin A2 gibi normal hemoglobin varyantlarında artma veya Hemoglobin S gibi anormal hemoglobin varyantlarının tespitinde tarama testi olarak başlıca alkali ve asit elektroforezi ile otomatize edilmiş yüksek basınçlı sıvı kromatografisi (HPLC) sistemleri kullanılır (6,8 (9). Elektroforez yöntemi ise daha fazla manuel işlem gerektirmesine, düşük konsantrasyonlardaki Hb A2 düzeyini belirlemede daha az sensitif olmasına ve uzun süren çalışma prosedürüne rağmen, nispeten düşük maliyeti ve yarı otomatize cihazların kullanıma girmesiyle tarama yöntemi olarak ülkemizde halen yaygın olarak kullanılmaktadır.…”
Section: Introductionunclassified