Abstract: PURPOSE:To evaluate the impact of the lens aberrations on the adaptive optics visual simulation of pseudophakic intraocular lens (IOL) profiles. METHODS:In 20 right phakic eyes, lens higher order aberrations (HOAs) were calculated as the whole eye minus the corneal aberrations. Visual simulation using low and high contrast corrected distance visual acuity (CDVA) testing was carried out with the VAO instrument (Voptica, SL, Murcia, Spain), considering three optical conditions of the lens: removing HOA (no lens-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 32 publications
0
5
0
Order By: Relevance
“…However, the cataractous lens will cease to be part of the postoperative optical system. While Villegas et al have shown that lenticular aberrations have an imperceptible effect on IOL profile simulations for a 3-mm pupil size [ 36 ], different types of cataract not only induce aberrations or alter the polarity of SA [ 37 ], but also cause intraocular scattering which pollutes the cataractous wavefront and reduces contrast sensitivity [ 38 ]. Since cataractous straylight can contaminate the preoperatively simulated pseudophakic retinal image, the adjunctive value of adaptive optics simulators remains to be comprehensively evaluated for differing patient demographics.…”
Section: Discussionmentioning
confidence: 99%
“…However, the cataractous lens will cease to be part of the postoperative optical system. While Villegas et al have shown that lenticular aberrations have an imperceptible effect on IOL profile simulations for a 3-mm pupil size [ 36 ], different types of cataract not only induce aberrations or alter the polarity of SA [ 37 ], but also cause intraocular scattering which pollutes the cataractous wavefront and reduces contrast sensitivity [ 38 ]. Since cataractous straylight can contaminate the preoperatively simulated pseudophakic retinal image, the adjunctive value of adaptive optics simulators remains to be comprehensively evaluated for differing patient demographics.…”
Section: Discussionmentioning
confidence: 99%
“…Patients with pupils smaller than 3 mm were excluded as the response of the human eye with pupils smaller than 3 mm to induced aberrations was insignificant, and hence, the VAO simulator was designed for a pupil size of 3 mm or greater. 29…”
Section: Methodsmentioning
confidence: 99%
“…Cataract represents the reduction of the transparency of the crystalline lens (1). Today, cataract is considered to be the most common cause of blindness in the world (2).…”
Section: Introductionmentioning