Effect of climate conditions on the thermodynamic performance of a data center cooling system under water-side economization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(6 citation statements)
references
References 42 publications
0
6
0
Order By: Relevance
“…Mahdi 7 compares the energy‐savings of three kinds of free cooling economizers in Iran and finds that the water‐side economizer shows the highest energy‐saving effect in Tabriz, Iran. Diaz 8 mainly compares the water‐side economizer's performance with an indirect evaporative cooler under different climate conditions. Agrawal 9 evaluates the effect of the water‐side economizer under different climate zones and compares the water consumption of the cooling system.…”
Section: Introductionmentioning
confidence: 99%
“…Mahdi 7 compares the energy‐savings of three kinds of free cooling economizers in Iran and finds that the water‐side economizer shows the highest energy‐saving effect in Tabriz, Iran. Diaz 8 mainly compares the water‐side economizer's performance with an indirect evaporative cooler under different climate conditions. Agrawal 9 evaluates the effect of the water‐side economizer under different climate zones and compares the water consumption of the cooling system.…”
Section: Introductionmentioning
confidence: 99%
“…Among the free cooling systems, WSE does not directly introduce outside air but rather produces chilled water using a cooling tower and heat exchanger. It is therefore often preferred because of the unlimited humidity conditions under which it can operate, or the inflow of contaminants from ambient environment, and for being more economical than ASE [6][7][8][9][10]. Accordingly, in recent years, there has been ongoing research in terms of applying WSE to data centers.…”
Section: Introductionmentioning
confidence: 99%
“…In a study by Diaz (2020), the potential of WSE was investigated for different climatic conditions in Chile [7]. The Annual average COP was increased by 7.8-9.7 compared to normal operation in a cool summer Mediterranean climate, while the annual average COP was the lowest in the desert climate.…”
Section: Introductionmentioning
confidence: 99%
“…Economizer control has significant energy saving potential in commercial buildings. Numerous studies recently explored the effect of diverse economizer control types on energy conservation [19][20][21][22][23][24][25][26][27][28][29][30][31]. Yao and Wang investigated the energy savings potential of temperature-based and enthalpy-based economizer cycles on VAV systems using a simulation program.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, some researchers focused on optimization-based strategies [28] and damper controls [23] to improve the energy efficiency of economizer controls. As for building type, economizer controls have been applied in a variety of building types, such as data centers [24][25][26][27], office buildings [19,21], and residential homes [28,29]. However, case studies of hospitals are still uncommon in the field of economizer research.…”
Section: Introductionmentioning
confidence: 99%