2017
DOI: 10.3390/ma10080851
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Alternating Current on the Cathodic Protection and Interface Structure of X80 Steel

Abstract: This study employs potential-monitoring techniques, cyclic voltammetry tests, alternating current (AC) voltammetry methods, and surface characterization to investigate the AC corrosion of cathodically protected X80 pipeline steel. In a non-passive neutral solution at pH 7.2, a sufficiently negative potential completely protects steel at an AC current density of 100 A/m2. In an alkaline solution at pH 9.6, more serious AC corrosion occurs at more negative cathodic protection (CP) potential, whereas without CP t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(17 citation statements)
references
References 64 publications
(91 reference statements)
0
17
0
Order By: Relevance
“…With the increasing development of high voltage power transmission, its sharing common grid with oil and gas pipelines has brought huge risk to pipeline integrity [ 1 , 2 ]. It has been acknowledged that AC interference can speed up the corrosion rate of most metals [ 3 ], but the actual mechanism of AC corrosion is not clear.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…With the increasing development of high voltage power transmission, its sharing common grid with oil and gas pipelines has brought huge risk to pipeline integrity [ 1 , 2 ]. It has been acknowledged that AC interference can speed up the corrosion rate of most metals [ 3 ], but the actual mechanism of AC corrosion is not clear.…”
Section: Introductionmentioning
confidence: 99%
“…Previous works [ 2 , 18 , 19 , 20 ] showed that AC affected the performance of CP system and caused deviation of CP potential from designed values. Hosokawa et al [ 18 ] and Kajiyama et al [ 19 ] reported that pipelines would suffer serious AC corrosion even if they satisfied the CP criterion potential of −0.85 V CSE (CSE corresponds to the copper sulfate electrode).…”
Section: Introductionmentioning
confidence: 99%
“…The weak adsorption of product has little effect on the cathodic scan. This is due to the adsorption of product which required the electrode reaction to provide more material for both diffusion process and adsorption process; therefore the peak occurred at more anodic potentials, in analogy with the succeeding chemical reaction [16,[22][23][24]. Table 4 lists the linear curve coefficients, f=y0+a*x and R-squared values for Figure 7 and Figure 8.…”
Section: Peak Current Functionmentioning
confidence: 99%
“…The existing studies concerning dynamic interference also indicated that the effect of the alternating cathodic process also played an important role in affecting the corrosion rate and corrosion morphology. [34][35][36][37][38][39] According to field measurement results, the fluctuation of pipe-to-soil potential and coupon current density could be beyond normal protection range resulting in increasing corrosion risk when the dynamic interference was severe. In the authors' previous work, [40] the corrosion behavior of X70 steel under the symmetric dynamic stray DC interference was investigated in simulated soil solutions.…”
Section: Introductionmentioning
confidence: 99%