2020
DOI: 10.1080/14670100.2020.1788859
|View full text |Cite
|
Sign up to set email alerts
|

Effect of age, electrode array, and time on cochlear implant impedances

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 32 publications
0
10
0
Order By: Relevance
“…Four-point impedance measurements are a relatively new marker in cochlear implantation which continue to be a focus for study (Bester et al 2020a). Results in animal and human studies have shown that impedance measurements can be used as a marker for fibrosis (Shepherd et al 1995; Duan et al 2004; Tykocinski et al 2005; O’Leary et al 2013; Wilk et al 2016; Chang et al 2017; Ishai et al 2017; Lo et al 2018; Shaul et al 2019; Briggs et al 2020; Velandia et al 2020). Compared to monopolar impedances, it is expected that the effect of the individual electrical tissue properties is minimized in four-point impedance measurements and thereby the local conductive environment between the electrodes can be assessed more accurately.…”
Section: Discussionmentioning
confidence: 99%
“…Four-point impedance measurements are a relatively new marker in cochlear implantation which continue to be a focus for study (Bester et al 2020a). Results in animal and human studies have shown that impedance measurements can be used as a marker for fibrosis (Shepherd et al 1995; Duan et al 2004; Tykocinski et al 2005; O’Leary et al 2013; Wilk et al 2016; Chang et al 2017; Ishai et al 2017; Lo et al 2018; Shaul et al 2019; Briggs et al 2020; Velandia et al 2020). Compared to monopolar impedances, it is expected that the effect of the individual electrical tissue properties is minimized in four-point impedance measurements and thereby the local conductive environment between the electrodes can be assessed more accurately.…”
Section: Discussionmentioning
confidence: 99%
“…33 For example, perimodiolar and lateral wall electrodes may vary in distance from the modiolus. 17 In addition, the use of a dexamethasone-eluting Cochlear Contour Advance electrode has been shown to determine different impedance values than standard electrodes. 34,35 These data suggest that intracochlear inflammation is present, and it can be modulated and it may influence impedance levels.…”
Section: Discussionmentioning
confidence: 99%
“…In general, the pattern of impedance values for each electrode is expected to be similar for all the four testing configurations. [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20] See ►Fig. 1 for a schematic explanation of the different coupling modes.…”
Section: Impedance Values Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Increasingly advanced speech processing strategies that deliver signals to the auditory nerve through a greater number of active electrodes with a better dynamic range favor more successful hearing, language, and speech development [37][38][39]. Therefore, the success of CI technology is logically connected with expert performance management of these devices, that is, the programming of their processors according to the specific needs of individual users.…”
Section: Predictors Of Cochlear Implantation Outcome In the Pediatric...mentioning
confidence: 99%