2021
DOI: 10.1016/j.aca.2021.338601
|View full text |Cite
|
Sign up to set email alerts
|

Effect of additives on cadmium chemical vapor generation and reliable quantification of generation efficiency

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
16
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(17 citation statements)
references
References 60 publications
1
16
0
Order By: Relevance
“…This enhancement factor was calculated as the ratio of the peak area sensitivity obtained with FI-PVG sample introduction to that arising from FI-PN during their concurrent operation; hence, both were measured under exactly the same plasma conditions. The nebulization efficiency was determined under optimal settings of the ICPMS (Table S1) using a modified waste collection method. ,,,, The overall PVG efficiency was also periodically estimated from the comparison of peak area sensitivities arising from FI introduction of a single Ru 3+ standard for PN and PVG, providing an immediate indication of the state of optimization of the PVG methodology; these values are given in the text without a corresponding SD.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…This enhancement factor was calculated as the ratio of the peak area sensitivity obtained with FI-PVG sample introduction to that arising from FI-PN during their concurrent operation; hence, both were measured under exactly the same plasma conditions. The nebulization efficiency was determined under optimal settings of the ICPMS (Table S1) using a modified waste collection method. ,,,, The overall PVG efficiency was also periodically estimated from the comparison of peak area sensitivities arising from FI introduction of a single Ru 3+ standard for PN and PVG, providing an immediate indication of the state of optimization of the PVG methodology; these values are given in the text without a corresponding SD.…”
Section: Methodsmentioning
confidence: 99%
“…The overall PVG efficiency was determined according to our previously published procedure 20,38,39,46,47 and is the product of a sensitivity enhancement factor and absolute nebulization efficiency. This enhancement factor was calculated as the ratio of the peak area sensitivity obtained with FI-PVG sample introduction to that arising from FI-PN during their concurrent operation; hence, both were measured under exactly the same plasma conditions.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
See 2 more Smart Citations
“…Quantification of the efficiency of the CVG of REEs in the presence of ARS was implemented with two methods according to the literature. 16 First, the waste from the CVG system was collected; the REE content inside was then quantitated and compared to those in the original solutions, to deduce the analyte transported to the ICP. Second, the overall efficiency was calculated as the product of nebulization efficiency (ca.…”
Section: ■ Introductionmentioning
confidence: 99%