Efektivitas Pengolahan Air Limbah Domestik Grey Water Dengan Proses Biofilter Anaerob dan Biofilter Aerob (Studi Kasus: IPAL INBIS Permata Bunda, Bontang)

Abstract: Domestic wastewater from non toilets is referred to as grey wastewater, domestic wastewater from bathing, washing and from the kitchen. Incubator Bisnis (INBIS) Permata Bunda is a forum for the application of entrepreneurial skills (apprenticeship) for people with disabilities residing in Kampung Aren, Bontang City, East Kalimantan. Grey wastewater treatment at INBIS Permata Bunda with a grease trap, filtration, sedimentation, anaerobic biofilter, aerobic biofilter, sedimentation and control. The research obje… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
2
0
6

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 5 publications
(5 reference statements)
0
2
0
6
Order By: Relevance
“…The concentration of wastewater for the textile industry does not exceed the quality standards, namely BOD <60 mg/L, COD <150 mg/L, TSS <50 mg/L, oil <3 mg/L, and pH > 6.0-9. The physico-biological wastewater treatment process has the effectiveness of reducing pollutants ranging from 56.73% -97.65% (Busyairi et al, 2020). This illustrates that wastewater treatment with the unit used can optimally reduce the pollutant materials in batik wastewater.…”
Section: Batik Wastewater Treatment Plant Building Designmentioning
confidence: 96%
See 1 more Smart Citation
“…The concentration of wastewater for the textile industry does not exceed the quality standards, namely BOD <60 mg/L, COD <150 mg/L, TSS <50 mg/L, oil <3 mg/L, and pH > 6.0-9. The physico-biological wastewater treatment process has the effectiveness of reducing pollutants ranging from 56.73% -97.65% (Busyairi et al, 2020). This illustrates that wastewater treatment with the unit used can optimally reduce the pollutant materials in batik wastewater.…”
Section: Batik Wastewater Treatment Plant Building Designmentioning
confidence: 96%
“…The physico-biological wastewater treatment process has the effectiveness of reducing pollutants ranging from 56.73% -97.65% and has met the quality standards for parameters, pH, BOD, COD, Ammonia, Fatty Oil and Total Coliform (Busyairi et al, 2020). Wastewater treatment using biological processes must maintain stability from wastewater discharge.…”
Section: Batik Wastewater Treatment Plant Building Designmentioning
confidence: 99%
“…Penelitian tersebut membandingkan pemakaian air dengan alat plambing konvensional dengan yang hemat air dimana disimpulkan bahwa pemakaian air menggunakan alat plambing nonkonvensional lebih kecil dibandingkan standar alat plambing konvensional dimana persentase penghematan mencapai 40,64% [5]. Penelitian lain dengan melakukan pengolahan air limbah domestik (grey water) yang dilakukan di Inkubator Bisnis (INBIS) Permata Bunda di Kampung Aren Kota Bontang Kalimantan Timur menyimpulkan bahwa pengolahan air mampu reduksi parameter pencemar antara 56,73-97,65% dan air hasil olahan dapat dimanfaatkan kembali mengingat telah memenuhi baku mutu untuk parameter, pH, BOD, COD, Amoniak, Minyak Lemak dan Total Coliform, namun untuk parameter TSS dan Total Coliform perlu evaluasi operasional [6]. Penelitian lain yaitu perencanaan sistem instalasi plambing air bersih, menggunakan aspek konservasi air dengan cara daur ulang air limbah dan pemanenan air hujan di Apartemen Cibinong Menara Matoa Tower E yang mampu menghemat air bersih sebesar 33% atau sekitar 305,88 m 3 /hari [7].…”
Section: Pendahuluanunclassified
“…Lumpur yang dihasilkan diolah di unit pengolahan lumpur dan akan diserahkan ke pihak ketiga berizin untuk ditangani sesuai dengan peraturan yang berlaku seperti disajikan pada Gambar 2. Pengolahan air limbah dengan menggunakan proses biologi telah diterapakan di Hotel Aston Braga City Walk [19], Mal X Kota Bandung [20], Gedung Rusunawa Mahasiswa Universitas Andalas [21], INBIS Permata Bunda, Bontang [22], dan Universitas Andalas Limau Manis Padang [23]. Berdasarkan hasil penelitian tersebut diperoleh hasil yang sesuai dengan baku mutu yang ditetapkan.…”
Section: Hasil Dan Pembahasanunclassified