2020
DOI: 10.1038/s41598-020-63161-x
|View full text |Cite
|
Sign up to set email alerts
|

Edge-subtraction X-ray ptychographic imaging with pink beam synchrotron radiation and a single photon-counting detector

Abstract: We present here a new method of performing X-ray edge-subtraction ptychographic imaging by combining multiple harmonics from an undulator synchtrotron source and an energy discriminating photon counting detector. Conventionally, monochromatic far-field X-ray ptychography is used to perform edge subtraction through the use of multiple monochromatic energy scans to obtain spectral information for a variety of applications. Here, we use directly the undulator spectrum from a synchrotron source, selecting two sepa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…The beamline is equipped with a triple-stripe mirror (Si, Pt, Ro), a metal filter box and a Si(111) double-crystal monochromator (DCM). The beamline can be operated either in monochromatic or pink beam mode by removing the DCM from the X-ray path (Batey et al, 2019;Brun, Di Trapani, Batey et al, 2020).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The beamline is equipped with a triple-stripe mirror (Si, Pt, Ro), a metal filter box and a Si(111) double-crystal monochromator (DCM). The beamline can be operated either in monochromatic or pink beam mode by removing the DCM from the X-ray path (Batey et al, 2019;Brun, Di Trapani, Batey et al, 2020).…”
Section: Methodsmentioning
confidence: 99%
“…In two-colours mode, Pixirad outputs two images in a single acquisition: one collects events with energy between thr 1 and thr 2 , the second collects events with energy above thr 2 . The detector has proved its effectiveness for single-shot K-edge subtraction computed tomography (KES-CT) with polychromatic laboratory sources (Brun, Di Trapani, Albers et al, 2020) and has been recently used as a harmonic selector for edge subtraction ptychographic imaging using synchrotron X-ray pink beam (Brun, Di Trapani, Batey et al, 2020).…”
Section: Pixirad Detectormentioning
confidence: 99%
“…As a result, these detectors can distinguish between X-ray photons in lower flux and background photons, achieving outstanding signal-tonoise relations. These features are particularly interesting for synchrotron applications, such as diffractometry [2], ptychography [3], and X-ray tomography [4].…”
Section: Introductionmentioning
confidence: 99%