Breast computed tomography (BCT) is an emerging application of X‐ray tomography in radiological practice. A few clinical prototypes are under evaluation in hospitals and new systems are under development aiming at improving spatial and contrast resolution and reducing delivered dose. At the same time, synchrotron‐radiation phase‐contrast mammography has been demonstrated to offer substantial advantages when compared with conventional mammography. At Elettra, the Italian synchrotron radiation facility, a clinical program of phase‐contrast BCT based on the free‐space propagation approach is under development. In this paper, full‐volume breast samples imaged with a beam energy of 32 keV delivering a mean glandular dose of 5 mGy are presented. The whole acquisition setup mimics a clinical study in order to evaluate its feasibility in terms of acquisition time and image quality. Acquisitions are performed using a high‐resolution CdTe photon‐counting detector and the projection data are processed via a phase‐retrieval algorithm. Tomographic reconstructions are compared with conventional mammographic images acquired prior to surgery and with histologic examinations. Results indicate that BCT with monochromatic beam and free‐space propagation phase‐contrast imaging provide relevant three‐dimensional insights of breast morphology at clinically acceptable doses and scan times.
X-ray phase imaging has the potential to dramatically improve soft tissue 30 contrast sensitivity, which is a crucial requirement in many diagnostic applications 31 such as breast imaging. In this context, a program devoted to perform in-vivo 32 phase-contrast synchrotron radiation breast computed tomography is ongoing at the 33 Elettra facility (Trieste, Italy). The used phase-contrast technique is the propagation-34 based configuration, which requires a spatially coherent source and a sufficient object-35 to-detector distance. In this work the effect of this distance on image quality is 36 quantitatively investigated scanning a large breast surgical specimen at 3 object-to-37 detector distances (1.6, 3, 9 m) and comparing the images both before and after 38 applying the phase-retrieval procedure. The sample is imaged at 30 keV with a 60 µm 39 pixel pitch CdTe single-photon-counting detector, positioned at a fixed distance of 40
A quantitative characterization of the soft tissues composing the human breast is achieved by means of a monochromatic CT phase-contrast imaging system, through accurate measurements of their attenuation coefficients within the energy range of interest for breast CT clinical examinations. Quantitative measurements of linear attenuation coefficients are performed on tomographic reconstructions of surgical samples, using monochromatic X-ray beams from a synchrotron source and a free space propagation setup. An online calibration is performed on the obtained reconstructions, in order to reassess the validity of the standard calibration procedure of the CT scanner. Three types of healthy tissues (adipose, glandular, and skin) and malignant tumors, when present, are considered from each sample. The measured attenuation coefficients are in very good agreement with the outcomes of similar studies available in the literature, although they span an energy range that was mostly neglected in the previous studies. No globally significant differences are observed between healthy and malignant dense tissues, although the number of considered samples does not appear sufficient to address the issue of a quantitative differentiation of tumors. The study assesses the viability of the proposed methodology for the measurement of linear attenuation coefficients, and provides a denser sampling of attenuation data in the energy range useful to breast CT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.