Edge loading in metal-on-metal hips: low clearance is a new risk factor

Abstract: The revision rate of large head metal-on-metal and resurfacing hips are significantly higher than conventional total hip replacements. The revision of these components has been linked to high wear caused by edge loading; which occurs when the head–cup contact patch extends over the cup rim. There are two current explanations for this; first, there is loss of entrainment of synovial fluid resulting in breakdown of the lubricating film and second, edge loading results in a large local increase in contact pressur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
109
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 95 publications
(112 citation statements)
references
References 29 publications
2
109
1
Order By: Relevance
“…During this period there is an increased risk of wear. Poorly aligned components will promote edge loading and increased contact pressures (Underwood et al, 2012); our results indicate these films are very sensitive to increased pressures (Myant et al, 2012). Edge loaded contacts may mimic scratch-like behaviour, completely stripping the surface film and accelerating wear.…”
Section: Implications For Hip Implant Lubricationmentioning
confidence: 71%
“…During this period there is an increased risk of wear. Poorly aligned components will promote edge loading and increased contact pressures (Underwood et al, 2012); our results indicate these films are very sensitive to increased pressures (Myant et al, 2012). Edge loaded contacts may mimic scratch-like behaviour, completely stripping the surface film and accelerating wear.…”
Section: Implications For Hip Implant Lubricationmentioning
confidence: 71%
“…Fisher11 has explained that adverse conditions that can cause rim contact in hip joint replacement relate to translational and rotational malpositioning of the bearing. With rotational malposition of the cup, such as the cup being positioned in steep inclination or with excessive anteversion, the contact patch developed at the bearing surface may intersect the cup rim, and this situation can be compounded by varied bearing designs such as sub‐hemispheric cups and lower bearing clearance or by deflection of the cup bearing during fixation 14. Additionally, translational malpositioning can produce a more severe contact condition and edge loading 15.…”
Section: Introductionmentioning
confidence: 99%
“…Second, we also learned that serum ion levels [16] vary between HRA designs. We used the Conserve 1 Plus prostheses in our study, and although one could infer that the same pathologic process may be occurring with other implants, our study remains limited to this specific device because coverage and radial clearance between femoral and acetabular components affect component wear [28] and the magnitude of the blend radius is likely to influence bone remodeling in hips with radiographic signs of impingement. Future aggregate research may provide a wider spectrum of the effects of impingement on CoS and CrS levels across multiple implants and identify which factors affect the susceptibility of a device to impingement and/or increased serum ion levels.…”
Section: Discussionmentioning
confidence: 99%