Easy to use and reliable technique for online dissolved oxygen tension measurement in shake flasks using infrared fluorescent oxygen-sensitive nanoparticles

Abstract: BackgroundDespite the progressive miniaturization of bioreactors for screening purposes, shake flasks are still widespread in biotechnological laboratories and industry as cultivation vessels. Shake flasks are often applied as the first or second step in applications such as strain screening or media optimization. Thus, there are ongoing efforts to develop online measurement techniques for shake flasks, to gain as much information as possible about the cultured microbial system. Since dissolved oxygen tension … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
31
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

5
2

Authors

Journals

citations
Cited by 21 publications
(31 citation statements)
references
References 42 publications
(64 reference statements)
0
31
0
Order By: Relevance
“…The applied fluorescence dye is immobilized in fluorescence sensor spots (OXSP5, Pyro Science GmbH, Aachen, Germany) [25, 26]. The red light excitation and infrared light emission is advantageous for avoiding biogenic fluorescences [27, 28]. For well-resolved oxygen partial pressure measurements during stop phases, every well is equipped with a respective optical fiber and a fluorescence sensor spot (Fig.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The applied fluorescence dye is immobilized in fluorescence sensor spots (OXSP5, Pyro Science GmbH, Aachen, Germany) [25, 26]. The red light excitation and infrared light emission is advantageous for avoiding biogenic fluorescences [27, 28]. For well-resolved oxygen partial pressure measurements during stop phases, every well is equipped with a respective optical fiber and a fluorescence sensor spot (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…For E. coli BL21 (DE3) pRotHi-YFP, two pre-cultivations were conducted according to the literature [17, 27, 28]. The first pre-cultivation on terrific broth (TB) medium was inoculated with 1 ml terrific broth (TB) cryocultures (200 g L −1 glycerol stocks, stock OD 600  = 1).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…3e–h, q–t. Due to the fact that the k L a estimation is fraught with high systematic errors at low respiration activities [36], the estimated k L a is very noisy at OTR values below 5 mmol L −1  h −1 . Accordingly, the most reliable k L a estimation is conducted during oxygen-limited conditions.…”
Section: Resultsmentioning
confidence: 99%
“…Both values were considered to be constants during cultivation. To test the sensitivity of the k L a determination, a Gaussian error propagation was performed as described in the literature [36]. The results are given in Eq.…”
Section: Methodsmentioning
confidence: 99%