Early Outcomes of the t-Branch Off-the-Shelf Multibranched Stent-Graft in Urgent Thoracoabdominal Aortic Aneurysm Repair

Abstract: Endovascular repair of urgent TAAA using the t-Branch is a feasible treatment option with acceptable 30-day mortality and morbidity in terms of SCI and renal function impairment. Adherence to the IFU prolonged procedure time but had no effect on outcomes. Increased experience of such cases over time may improve outcomes.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
35
1
2

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 68 publications
(40 citation statements)
references
References 29 publications
1
35
1
2
Order By: Relevance
“…The t-Branch device has proved to be a successful therapy but still carries a 6% to 14% 30-day mortality and a 6% to 21% rate of spinal cord ischemia. 4 , 5 When it is used to treat aortic rupture, the success of the t-Branch device depends on an expeditious operative time. In the recent experience of Spanos et al 5 reporting t-Branch use in urgent TAAA, mean operative time of experienced users was 407 minutes and as high as 497 minutes in technically challenging cases.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The t-Branch device has proved to be a successful therapy but still carries a 6% to 14% 30-day mortality and a 6% to 21% rate of spinal cord ischemia. 4 , 5 When it is used to treat aortic rupture, the success of the t-Branch device depends on an expeditious operative time. In the recent experience of Spanos et al 5 reporting t-Branch use in urgent TAAA, mean operative time of experienced users was 407 minutes and as high as 497 minutes in technically challenging cases.…”
Section: Discussionmentioning
confidence: 99%
“… 4 , 5 When it is used to treat aortic rupture, the success of the t-Branch device depends on an expeditious operative time. In the recent experience of Spanos et al 5 reporting t-Branch use in urgent TAAA, mean operative time of experienced users was 407 minutes and as high as 497 minutes in technically challenging cases. The ability to cannulate branch vessels expeditiously from a single access reduced the operative time to 98 minutes in our case.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Die [17], zeigte ähnlich zu den Ergebnissen der elektiven Verfahren einen technischen Erfolg in 93 % der Fälle. Von 155 Zielgefäßen wurden 151 erfolgreich katheterisiert (97,4 %) und die Branches blieben zu 99 % innerhalb des 1.…”
Section: Einführungunclassified
“…For urgent cases with para/suprarenal aneurysms, surgeon modified fenestrated and branched stent grafts, or for the thoraco-abdominal aneurysms off the shelf multi-branched endografts (t-Branch, Cook Medical, Bloomington IN, USA), were used. 16,17 For the surgeon modified stent grafts an off the shelf thoracic stent graft was chosen and the necessary opening and reinforcement of all fenestrations was performed on the back table, while the patient was prepared for the procedure. 17…”
Section: Stent Graftsmentioning