1998
DOI: 10.1006/jcis.1997.5386
|View full text |Cite
|
Sign up to set email alerts
|

Dynamics of Polymeric Solid Surfaces Treated with Oxygen Plasma: Effect of Aging Media after Plasma Treatment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

9
136
3

Year Published

2001
2001
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 162 publications
(148 citation statements)
references
References 22 publications
(13 reference statements)
9
136
3
Order By: Relevance
“…We observed that leaving the plasma treated substrates in air prior to bonding them for times as short as 5 min, resulted in decreased quality of adhesion. This observation was consistent with the expected rearrangement of the oxidized polymer chains at the PDMS surface (Morra et al 1990;Murakami et al 1998). …”
Section: Plasma Treatmentsupporting
confidence: 79%
See 1 more Smart Citation
“…We observed that leaving the plasma treated substrates in air prior to bonding them for times as short as 5 min, resulted in decreased quality of adhesion. This observation was consistent with the expected rearrangement of the oxidized polymer chains at the PDMS surface (Morra et al 1990;Murakami et al 1998). …”
Section: Plasma Treatmentsupporting
confidence: 79%
“…The hydrophilic nature of such partially oxidized PDMS surfaces makes them unstable when exposed to hydrophobic medium, such as air (Morra et al 1990;Murakami et al 1998). Within hours, conformational rearrangements pull the partially oxidized polymer chains into the PDMS bulk and/or low-molecular weight nonoxidized polymer chains diffuse to the surface (Eddington et al 2006) leading to (1) surfaces covered with non-oxidized PDMS chains, (2) recovery of the surface hydrophobicity, and (3) loss of the PDMS adhesiveness.…”
Section: Plasma Treatments and Quality Of Adhesionmentioning
confidence: 99%
“…15,25,26 Oxygen-containing species are present even on native surfaces of "unoxidized" PS (not UVO oxidized) because surface oxidation occurs naturally for samples aging under ambient laboratory conditions; 29 native PS petri dishes have typically ∼1 atom % oxygen on their surface. 30,31 The oxidation of PS is restricted to its surface because the kinetics of oxidation of the surface of PS is much faster than that of the bulk as a consequence of the limited depth of penetration of UV light and the limited diffusion of ozone into the bulk. 28 Using measurements of contact angles, we correlated the concentrations N ox 's of oxygen-containing species on the surfaces of PS ox to the times of oxidation t ox 's (Figure 4a).…”
Section: I) the Numbers Of Oxygen-containing Groups Present On The Sumentioning
confidence: 99%
“…The fluorine content decreased by 6% when samples were simply stored in ambient conditions for 30 days pointing towards a re-orientation/migration of the fluorine groups away from the surface during aging. The introduction of functional groups onto the surface of silicone has been recognized to lack stability due to the reorganization of silicone elastomers over time [26,27,29,31,32]. The phenomena of hydrophobic recovery upon PDMS plasma oxidation has been extensively investigated, and explained namely by the reorientation of surface hydrophilic groups towards the bulk and/or reorientation of non-polar groups in the bulk towards the surface, by the diffusion of pre-existing low molecular weight (LMW) species through the bulk to the surface, or migration of created LMW species during treatment to the surface [26].…”
Section: Chemical Composition and Stabilitymentioning
confidence: 99%