1995
DOI: 10.1109/51.473272
|View full text |Cite
|
Sign up to set email alerts
|

Dynamical infrared thermography in humans

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
27
0
1

Year Published

2004
2004
2017
2017

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(29 citation statements)
references
References 5 publications
1
27
0
1
Order By: Relevance
“…Various filters (in both time and frequency domains) and algorithms are used for minimizing noise, reducing blurring and edge preservation in thermal images [94]. Gulyaev et al suggested four fundamental numerical operations on the thermograms to increase accuracy of the data extracted from them [95]. These four operations are, (i) subtraction of background in each frame of interest, (ii) construction of temperature time profile at chosen point or regions, (iii) spatio-temporal projections of image sequences and (iv) calculation of time derivative of temperature data.…”
Section: Researchers [Ref]mentioning
confidence: 99%
See 1 more Smart Citation
“…Various filters (in both time and frequency domains) and algorithms are used for minimizing noise, reducing blurring and edge preservation in thermal images [94]. Gulyaev et al suggested four fundamental numerical operations on the thermograms to increase accuracy of the data extracted from them [95]. These four operations are, (i) subtraction of background in each frame of interest, (ii) construction of temperature time profile at chosen point or regions, (iii) spatio-temporal projections of image sequences and (iv) calculation of time derivative of temperature data.…”
Section: Researchers [Ref]mentioning
confidence: 99%
“…Bouzida et al [5] 2009 Thermoregulation FLIR Phoenix Model Park et al [49] 2007 Shoulder impingement syndrome IRIS 5000 (Medicore, Seoul, Korea) Brioschi et al [104] 2007 3D MRI and IR image fusion Agema Thermovision 470 and ThermaCAM P65HS (FLIR Systems) Sun et al [107] 2006 Diabetic at-risk feet Spectrum 9000 MB; Bio vision technologies, Inc. Taipei, Taiwan Deng and Liu [35] 2005 Effect of induced evaporation on thermal diagnostics of tumors HR-II Medical Infrared Imaging System, Institute of Optics and Electronics of North China Hosaki et al [33] 2002 Peripheral circulation in subjects with diabetes mellitus Infrared ray thermo tracer 6T66 (NEC-Sanei Co. Japan) Lo [63] 2002 Acupuncture Meditherm 2000 Shevelev [45] 1998 Functional imaging of brain AGA Thermovision 780 M Armstrong et al [26] 1997 High risk diabetic foot Exergen DT 1001 infrared skin temperature probe Carlo [48] 1995 Clinical and experimental dermatology AGA Thermovision 680 Gulyaev et al [95] 1995 and simultaneous large area monitoring is possible. Interpretations from pseudo color coded thermograms are easier and faster.…”
Section: 2009mentioning
confidence: 99%
“…27 This process has been widely used to characterize temperature patterns of the body surface in the diagnosis of several diseases, and it could represent a valuable instrument for the analysis of biological tissues and physiological researches concerning the study of production and dissipation of heat during and after exercise. 7,8,27 Infrared thermography overcomes limitations observed in other methods that require physical contact to measure the temperature, 27,28 and it could offer indirect hemodynamic recruitment information of muscle masses during the process of exercise-related thermal adjustment. 17 The thermal changes that occurred in deep areas of the body are transferred to the superficial tissue by the blood circulation.…”
Section: Introductionmentioning
confidence: 98%
“…The thermal technology only not has got wide application in current medical treatment, but also infuses the medical science with fresh vigor at the same time. (Gulyaev et al, 1995). Especially, theory and method of thermal science combine with TCM has become a new cut-in point into bio-heat transfer research.…”
Section: Introductionmentioning
confidence: 98%