2016
DOI: 10.1109/tpwrd.2015.2512178
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic Interactions of the MMC-HVDC Grid and its Host AC System Due to AC-Side Disturbances

Abstract: Abstract-This paper investigates the dynamic interactions of a Modular Multi-level Converter (MMC) -based HVDC grid and its host AC system during AC-side disturbances. The HVDC grid is composed of five MMC stations that are interconnected through a network of cables and over-head lines. The AC grid includes ten turbine-generators. The studies are conducted in the PSCAD platform, including the detailed models of the AC and DC subsystems.The reported case studies indicate that without the HVDC supplementary con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 49 publications
(26 citation statements)
references
References 22 publications
0
25
0
1
Order By: Relevance
“…This section will outline the MTDC grid control schemes necessary to enable reconfigurability during DC outage contingencies. Full details of standard controls for VSC-HVDC are not discussed in detail but can be found in [9]- [15].…”
Section: Mtdc Grid Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…This section will outline the MTDC grid control schemes necessary to enable reconfigurability during DC outage contingencies. Full details of standard controls for VSC-HVDC are not discussed in detail but can be found in [9]- [15].…”
Section: Mtdc Grid Controlmentioning
confidence: 99%
“…The adaptive scheme of droop control strategy and the impacts of the autonomous control during transient events are reported in [8]. The dynamic interaction between the Modular Multilevel Converter (MMC) based MTDC grid and AC system is presented in [9] with a DC voltage droop to maintain the voltage stability of the DC system. The VSC-HVDC system control parameters and their impacts on the stability of the AC system in the electromechanical time-frame are discussed in [10].…”
Section: Introductionmentioning
confidence: 99%
“…Dynamic interactions of MMC‐based HVDC network are analysed in Ajaei and Iravani during AC‐side disturbances. Transient behaviour of entire network is also investigated.…”
Section: Application Areasmentioning
confidence: 99%
“…The DC network includes overhead lines and underground cables. Details of the HVDC grid and its parameters are given in [10] and Table I. The positive direction of power is assumed from the AC side to the DC side.…”
Section: A Test Systemmentioning
confidence: 99%
“…6. After 1 ms, the fault is detected and the DC transmission line is tripped out by the corresponding DC circuit breakers after another 1 ms [10]. Fig.…”
Section: Performance Evaluationmentioning
confidence: 99%