Dynamic Eccentricities in Pushover Analysis of Asymmetric Single-Storey Buildings

Abstract: Α new version about a method of documented application of pushover analysis on asymmetric single-storey buildings has been presented, recently. The main target of this new method was to rationally consider the coupling between torsional (about vertical axis) and translational vibrations of asymmetric singlestorey building diaphragm under translational seismic excitation of its base. For this reason, the equivalent lateral static floor force according to the new method is applied using suitable dynamic eccentri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
3

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
1
1

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 10 publications
0
6
0
3
Order By: Relevance
“…Then, the following have been calculated: (a) the in-plan location of the "Capable Near Collapse Centre of Stiffness" CR sec , (b) the orientation of the horizontal "Capable Near Collapse Principal Axes" sec and sec , (c) the "Capable Near Collapse Torsional Radii" Ι,sec and ΙI,sec relative to the horizontal axes sec and sec as well as the radius of gyration m of the diaphragm, and (d) the torsional sensitivity of the model according to the relationship Ι,sec or ΙI,sec ≤ 1.10 m . Finally, using the previous data, the inelastic dynamic eccentricities plus the accidental ones, namely the inelastic design eccentricities of the Forced-Based pushover procedure, have been calculated from Equations (1-4) and (5)(6)(7)(8), respectively. Also, the floor enforced displacements of the Displacement-Based procedure are determined using Figures 1 and 3.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Then, the following have been calculated: (a) the in-plan location of the "Capable Near Collapse Centre of Stiffness" CR sec , (b) the orientation of the horizontal "Capable Near Collapse Principal Axes" sec and sec , (c) the "Capable Near Collapse Torsional Radii" Ι,sec and ΙI,sec relative to the horizontal axes sec and sec as well as the radius of gyration m of the diaphragm, and (d) the torsional sensitivity of the model according to the relationship Ι,sec or ΙI,sec ≤ 1.10 m . Finally, using the previous data, the inelastic dynamic eccentricities plus the accidental ones, namely the inelastic design eccentricities of the Forced-Based pushover procedure, have been calculated from Equations (1-4) and (5)(6)(7)(8), respectively. Also, the floor enforced displacements of the Displacement-Based procedure are determined using Figures 1 and 3.…”
Section: Discussionmentioning
confidence: 99%
“…First, by applying the floor lateral static force on the location of the Centre of Mass (CM) that is shifted by the accidental eccentricity, the phenomenon of the development of floor-diaphragm torsional vibration about vertical axis coupled to translational ones cannot be rationally considered. With other words, this phenomenon, occurring both in linear and in non-linear areas, is seriously underestimated, especially in torsionally-flexible buildings, because of the inability to obtain the actual inertial torsional moment of the floordiaphragm [3][4][5][6][7][8][9][10]. Second, EN 1998-1 does not provide any detailed information about the building principal axes and refers to the international literature (although it is emphasized at various points that the lateral loads should be applied along the principal axes of the building) and thus it is unclear which is the appropriate orientation of the lateral static forces in the framework of pushover analysis.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…2.18 και 2. 19). Αυτό έχει ως συνέπεια η σχέση δύναμης-μετακίνησης του MDoF συστήματος (διάγραμμα V-Dn) να ισχύει επίσης και για το ισοδύναμο SDoF σύστημα (διάγραμμα F * -D * ), αφού πρώτα και η δύναμη και η μετακίνηση διαιρεθούν με το Γ. H απεικόνιση της τελευταίας σχέσης μπορεί να επιτευχθεί αλλάζοντας την κλίμακα και στους δύο άξονες του διαγράμματος δύναμης-μετακίνησης.…”
Section: )unclassified
“…Η προτεινόμενη διαδικασία αναπτύσσεται αρχικά για τα μονώροφα ασύμμετρα κτίρια ο/σ και κατόπιν επεκτείνεται στα πολυώροφα ασύμμετρα κτίρια ο/σ. Στοιχεία της προτεινόμενης διαδικασίας έχουν ήδη προδημοσιευτεί στις εργασίες Bakalis & Makarios [2017, 2019 Όσον αφορά το τέταρτο ερώτημα, ο ΕΝ 1998-1 στην παράγραφο 4.3.3.5 γενικά επιβάλλει την θεώρηση της χωρικής δράσης των δύο οριζόντιων συνιστωσών της σεισμικής δράσης και προτείνει αυτή να λαμβάνεται με επαλληλίες, εντός της μη-γραμμικής περιοχής, δια μέσω συνδυασμών SRSS (τετραγωνική ρίζα του αθροίσματος των τετραγώνων) ή γραμμικών συνδυασμών των μεγεθών έντασης/παραμόρφωσης που προκύπτουν από τις χωριστές σε κάθε εξεταζόμενη διεύθυνση μη-γραμμικές στατικές αναλύσεις. Εδώ το πρόβλημα εντοπίζεται στο γεγονός ότι γενικά οι επαλληλίες απαγορεύονται αυστηρά στη μη-γραμμική περιοχή συμπεριφοράς.…”
Section: κεφαλαιο 4: προτεινομενη διαδικασια μη-γραμμικης στατικης αναλυσης με τη χρηση ανελαστικων δυναμικων εκκεντροτητων 41 εισαγωγήunclassified