2020
DOI: 10.1016/j.measurement.2020.107805
|View full text |Cite
|
Sign up to set email alerts
|

Dual-sensing and dual-frequency microwave SRR sensor for liquid samples permittivity detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
61
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 128 publications
(68 citation statements)
references
References 87 publications
0
61
0
Order By: Relevance
“…On the other hand, Dip 2 exhibits a higher sensitivity (29.3 kHz/%rh) with lower calibration fit residuals in comparison to Dip 1: ± 100 kHz, or ± 3.4 %rh. As an alternative, it is possible to use both dips for humidity detection, thereby reducing the measurement error and increasing accuracy [37].…”
Section: Resultsmentioning
confidence: 99%
“…On the other hand, Dip 2 exhibits a higher sensitivity (29.3 kHz/%rh) with lower calibration fit residuals in comparison to Dip 1: ± 100 kHz, or ± 3.4 %rh. As an alternative, it is possible to use both dips for humidity detection, thereby reducing the measurement error and increasing accuracy [37].…”
Section: Resultsmentioning
confidence: 99%
“…It also shows the detection range of the complex permittivity for each designed sensor aligned with the resonance frequency for a bare sensor and the unloaded, and loaded conditions. It can be illustrated that the maximum normalized sensitivity was achieved by [ 11 , 12 , 75 , 95 , 99 ]. As reported by Ebrahimi, Scott and Ghorbani [ 12 ], the sensitivity was enhanced by incorporating one capacitor in the resonator sensor, while Abdolrazzaghi, Daneshmand and Iyer [ 95 ] substituted the conventional microwave couplers with metamaterial-based couplers to enhance the sensitivity.…”
Section: Discussion and Research Challengesmentioning
confidence: 99%
“…To demonstrate a high accuracy, Kiani, Rezaei and Navaei [ 75 ] designed a dual-sensing at dual frequencies-based SRR sensor for liquid sample permittivity detection. This sensor has the capability of measuring one tested sample using two frequency bands, which decreases the measurement error caused by a single frequency.…”
Section: Recent Developments Of Microwave Planar Resonatorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Table I compares the fabricated prototype to recently reported microwave microfluidic sensors, either utilizing additive manufacturing or capable of sensing multiple fluids. While dual-mode resonators were proposed in [38] and [39], the proposed sensor is the only scalable multi-fluid microwave sensor proposed in literature. In addition to being the only reported sensor with >2 microfluidic channels and resonant elements, the proposed sensor's accuracy and sensitivity is comparable to state-of-the-art sensors which utilize additive manufacturing.…”
Section: Discussion and Comparison With Recent Sensorsmentioning
confidence: 99%