2020
DOI: 10.1016/j.renene.2019.09.042
|View full text |Cite
|
Sign up to set email alerts
|

Dspace DS1104 implementation of a robust nonlinear controller applied for DFIG driven by wind turbine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
24
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 39 publications
(25 citation statements)
references
References 15 publications
1
24
0
Order By: Relevance
“…Substituting the expression of the rotor flux (12) into the expression of the rotor voltage (11), we get: (13) Analyzing the expression of the rotor voltage in eq. 13, we can see that it is decomposed into two terms, the first term A is the electromotive force (EMF) induced by the stator flux [2], when the current rotor is equal to zero I r = 0 in the open circuit, the term A can be defined as:…”
Section: Doubly-fed Induction Generator Under Voltage Dips 21 Modelimentioning
confidence: 99%
See 2 more Smart Citations
“…Substituting the expression of the rotor flux (12) into the expression of the rotor voltage (11), we get: (13) Analyzing the expression of the rotor voltage in eq. 13, we can see that it is decomposed into two terms, the first term A is the electromotive force (EMF) induced by the stator flux [2], when the current rotor is equal to zero I r = 0 in the open circuit, the term A can be defined as:…”
Section: Doubly-fed Induction Generator Under Voltage Dips 21 Modelimentioning
confidence: 99%
“…DFIG is a highly nonlinear system, so several control strategies have been examined to improve the DFIG operation under disturbances [6][7][8][9][10][11]. Among these control techniques, the most used one is the classical control based on the proportional-integral (PI) correctors, it's very used for it reliability and simplicity of implementation, but its performance degrades when the internal generator parameters varied [12,13]. In work [6], a nonlinear MPPT control of a DFIG based on feedback linearization control (FLC) was designed, and the stability of the system was achieved using Lyapunov theory.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…According to the grid code requirements, if the grid voltage is subjected to a sag of <90% and >10% of its rated value during faults [28 ], then the WECS should be subjected to FRT. Hence, a DVR unit is installed for detection of balance/unbalance faults and for the improvement of the FRT capability of the system.…”
Section: Grid Faults and Dynamic Voltage Restorermentioning
confidence: 99%
“…The authors proposed a nonlinear back-stepping approach based MPPT method which is simple in structure and guarantees the robustness to parametric uncertainties. 26,27 The authors in 28 proposed a sliding mode control supervised adaptive fractional order control system for the rotor and grid side converters in DFIG based WECS. In their investigation, the simulation results are presented and compared with the basic sliding mode and the conventional PI controllers to show the effectiveness of the application of the fractional order controller.…”
Section: Introductionmentioning
confidence: 99%