Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam

Abstract: The aim of this work was to evaluate the performance of the voxel-based Monte Carlo algorithm implemented in the commercial treatment planning system ONCENTRA MASTERPLAN for a 9 MeV electron beam produced by a linear accelerator Varian Clinac 2100 C/D. In order to realize an experimental verification of the computed data, three different groups of tests were planned. The first set was performed in a water phantom to investigate standard fields, custom inserts, and extended treatment distances. The second one c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 27 publications
0
7
0
Order By: Relevance
“…There are various commercially available systems that utilise MC algorithms for dose calculations. Examples of such MC-based treatment planning softwares are MasterPlan, eMC and Eclipse 6 8 . However there are other systems for electron treatment planning which may suffer from large uncertainties, especially when they are applied to an inhomogeneous media.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…There are various commercially available systems that utilise MC algorithms for dose calculations. Examples of such MC-based treatment planning softwares are MasterPlan, eMC and Eclipse 6 8 . However there are other systems for electron treatment planning which may suffer from large uncertainties, especially when they are applied to an inhomogeneous media.…”
Section: Introductionmentioning
confidence: 99%
“…Examples of such MC-based treatment planning softwares are MasterPlan, eMC and Eclipse. [6][7][8] However there are other systems for electron treatment planning which may suffer from large uncertainties, especially when they are applied to an inhomogeneous media. Such treatment planning systems use different algorithms such as pencil beam algorithm and they have limitations in predicting hot and cold spots in inhomogeneous regions.…”
Section: Introductionmentioning
confidence: 99%
“…Due to the implementation of new Monte Carlo based dose calculation algorithms, 18 there is an increasing interest in validating and commissioning these algorithms, [19][20][21] requiring a better knowledge about the depth dependence of perturbation corrections in electron dosimetry. The presence of an energy and depth dependence of perturbation corrections for parallel-plate chambers in clinical electron dosimetry has been shown in recent years by several authors.…”
Section: Introductionmentioning
confidence: 99%
“…Although conventional radiographs, because they are two-dimensional, do not allow the qualitative visualization of images with high magnification (up to 300,000 X) and resolution, nor the observation and recording of three-dimensional images such as scanning electron microscopy -SEM (PICON et al, 2006). Therefore, studies using SEM in bone tissues allow the analysis of the bone architecture, bone neoformation and, in cases of bone repair, its maturation (CRUZ et al, 2007;SCHIAPPARELLI;ZEFIRO;TACCINI, 2009). Given the circumstances of the environ ent where the spe i en w s foun ro o ern u o r i in region of wor s of transposition of the São Francisco River and thereby, the presence of furrows, irregularities and bone protrusions on the surface of the distal epiphysis of the humerus can be observed through SEM, confirming that the case involved thoracic limb amputation after traumatic injury and not ectromelia.…”
Section: Discussionmentioning