2013
DOI: 10.1016/j.prro.2012.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric and cost comparison of first fraction imaging versus fractional re-imaging on critical organ dose in vaginal cuff brachytherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 14 publications
1
6
0
Order By: Relevance
“…ABS guidelines do not demand that each fraction of VCB is planned because there is an assumed fixed geometry of the implant. Image at each fraction of three increments costs 35% compared with a single simulation but did not produce any dosimetric advantage 95. Similar results with single-channel or multichannel cylinders were observed; imaging at each fraction was 19% and 22% more expensive, respectively 96.…”
Section: Custom or Standard Radiotherapy Planningsupporting
confidence: 61%
“…ABS guidelines do not demand that each fraction of VCB is planned because there is an assumed fixed geometry of the implant. Image at each fraction of three increments costs 35% compared with a single simulation but did not produce any dosimetric advantage 95. Similar results with single-channel or multichannel cylinders were observed; imaging at each fraction was 19% and 22% more expensive, respectively 96.…”
Section: Custom or Standard Radiotherapy Planningsupporting
confidence: 61%
“…Multiple studies evaluated 3D treatment planning at the first fraction only or for each fraction. They show that 3D planning for each fraction does not decrease dose to the normal tissues but incurs greater expense than performing 3D planning for the first fraction only [102104]. CT-based treatment planning effectively allows assessment of air gaps between the applicator and the vaginal cuff prior to treatment delivery [105].…”
Section: Vaginal Brachytherapy Treatment Deliverymentioning
confidence: 99%
“…It’s reasonable to hypothesize that the extra-tension could act as another source of displacement of vaginal vault, which was not controlled in our analysis, but should be tested in future studies. However, other studies suggest that the evaluation of the first insertion is sufficient in terms of dose reporting 9 18 ; this is the current approach at our institution. Another limitation is the absence of a documented manometer reading, which can measure various levels of tension and help reproduce the findings of our study.…”
Section: Discussionmentioning
confidence: 97%