This work indicates the potential for markerless tumor tracking utilizing DE fluoroscopy. With DE imaging, the algorithm showed improved detectability vs SE fluoroscopy and was able to accurately track the tumor in nearly all cases.
To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R² = 0.99). Respective values for the average DSC, NDSC(1 mm) and NDSC(2 mm) for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between clinically acquired SPECT perfusion and specific ventilation from 4D CT. Results suggest high correlation between methods within the sub-population of lung cancer patients with malignant airway stenosis.
Dual energy (DE) imaging consists of obtaining kilovoltage (kV) x-ray images at two different diagnostic energies and performing a weighted subtraction of these images. A third image is then produced that highlights soft tissue. DE imaging has been used by radiologists to aid in the detection of lung malignancies. However, it has not been used clinically in radiotherapy. The goal of this study is to assess the feasibility of performing DE imaging using a commercial on-board imaging system. Both a simple and an anthropomorphic phantom were constructed for this analysis. Planar kV images of the phantoms were obtained using varied imaging energies and mAs. Software was written to perform DE subtraction using empirically determined weighting factors. Tumor detectability was assessed quantitatively using the signal-difference-tonoise ratio (SDNR). Overall DE subtraction suppressed high density objects in both phantoms. The optimal imaging technique, providing the largest SDNR with a dose less than our reference technique was 140 kVp, 1.0 mAs and 60 kVp, 3.2 mAs. Based on this analysis, DE subtraction imaging is feasible using a commercial on-board imaging system and may improve the visualization of tumors in lung cancer patients undergoing image-guided radiotherapy.
This article aims to review the risk stratification of endometrial cancer, treatment rationale, outcomes, treatment planning, and treatment recommendations of vaginal brachytherapy (VBT) in the post-operative management of endometrial cancer patients. The authors performed a thorough review of the literature and reference pertinent articles pertaining to the aims of this review. Adjuvant VBT for early stage endometrial cancer patients results in very low rates of vaginal recurrence (0–3.1%) with low rates of late toxicity which are primarily vaginal in nature. PORTEC-2 supports that VBT results in non-inferior rates of vaginal recurrence compared to external beam radiotherapy (EBRT) for the treatment of high-intermediate risk patients. VBT as a boost following EBRT, in combination with chemotherapy, and for high-risk histologies have shown excellent results as well though randomized data do not exist supporting VBT boost. There are many different applicators, dose-fractionation schedules, and treatment planning techniques which all result in favorable clinical outcomes and low rates of toxicity. Recommendations have been published by the American Brachytherapy Society and the American Society of Radiation Oncology to help guide practitioners in the use of VBT. Data support that patients and physicians both prefer joint decision-making regarding the use of VBT, and patients often desire additional treatment for a marginal benefit in risk of recurrence. Discussions regarding adjuvant therapy for endometrial cancer are best performed in a multi-disciplinary setting and patients should be counseled properly regarding the risks and benefits of adjuvant therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.