Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2022
DOI: 10.3390/standards2030019
|View full text |Cite
|
Sign up to set email alerts
|

Does Standardisation Ensure a Reliable Assessment of the Performance of Construction Products?

Abstract: The implementation of a standard should be preceded by research work aimed at developing the test method, particularly in validation experiments. Is it actually so? Numerous experiences of producers and labs and an increasing number of scientific works prove the opposite. It turns out that some standard methods are very poorly suited to assessing the performance of construction products. This is related both to the specificity of the methods and the tested products. This article presents some product assessmen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0
7

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(22 citation statements)
references
References 22 publications
0
15
0
7
Order By: Relevance
“…These values were lower than the condition for the laboratory to obtain a positive assessment [not causing a warning signal] set as |z| ≤ 2 (41). During the verifi cation by the construction market surveillance authorities of the correctness of the AVCP performed by the manufacturer, any result below 1.0 N/mm 2 for CTA class C2 would be negative (30,41,63).…”
Section: Results and Their Analysismentioning
confidence: 88%
See 1 more Smart Citation
“…These values were lower than the condition for the laboratory to obtain a positive assessment [not causing a warning signal] set as |z| ≤ 2 (41). During the verifi cation by the construction market surveillance authorities of the correctness of the AVCP performed by the manufacturer, any result below 1.0 N/mm 2 for CTA class C2 would be negative (30,41,63).…”
Section: Results and Their Analysismentioning
confidence: 88%
“…We (41). Podczas weryfi kacji, przez organy nadzoru rynku budowlanego, prawidłowości AVCP dokonanej przez producenta, każdy wynik poniżej 1,0 N/mm 2 dla CTA klasy C2 zostałby sklasyfi kowany jako negatywny (30,41,63).…”
Section: Results and Their Analysisunclassified
“…Measurements of construction products and, thus, carrying out PT/ILC, due to the multi-stage nature of the test procedures, product heterogeneity, and when the methods used are destructive tests, are additionally complex. Thus, the conformity assessment is even more difficult—it often raises the question of to what extent the evaluation of the construction product based on the tests is reliable in the case of construction products [ 20 , 21 , 22 ]. Notably, the opinion of the laboratory often plays a decisive role—this is the case in the assessment of construction products collected from the market by market surveillance authorities and checking whether the product meets the parameters declared by the manufacturer [ 19 , 23 , 24 ].…”
Section: Introductionmentioning
confidence: 99%
“…Często pomiary wyrobów budowlanych, a tym samym PT/ILC, nastręczają wiele trudności, przede wszystkim, ze względu na wieloetapowy charakter procedur badawczych, niejednorodność wyrobu oraz gdy stosuje się niszczące metody badań (25). Od kilku lat formułowane jest pytanie na ile ocena niektórych wyrobów budowlanych w pewnych przypadkach jest wiarygodna (26,27).…”
Section: Introductionunclassified
“…Usually, measurements of construction products, and thus PT/ILC, pose many diffi culties, mainly due to the multi-stage nature of test procedures, product heterogeneity, and when the methods used are destructive (25). For several years, the question has been raised as to what extent the assessment of certain construction products is reliable in some instances (26,27).…”
Section: Introductionmentioning
confidence: 99%