2006
DOI: 10.1007/s10554-006-9101-z
|View full text |Cite
|
Sign up to set email alerts
|

Disturbed Endothelial Function of the Internal Thoracic Artery in Patients with Coronary Artery Disease

Abstract: We demonstrated, that patients with coronary artery disease have a higher peripheral resistance and a lower diastolic velocity of the internal thoracic artery during stress testing. This corresponds to a disturbed vasomotion and may be an early marker of arteriosclerosis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0
1

Year Published

2008
2008
2008
2008

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 28 publications
0
1
0
1
Order By: Relevance
“…Coronary stenting does result in a greater degree of impairment of endothelial function and coronary vasodilatory reserve than balloon angioplasty [13][14][15], and these may cause distal particulate embolization from the targeted lesion, the release of vasoactive substances such as serotonin due to platelet activation, and increased inflammatory response at sites of stent implantation [16][17][18]. Such mechanisms have been attributed to the greater inflation pressures and vessel wall disruption associated with stent implantation.…”
Section: Discussionmentioning
confidence: 99%
“…Coronary stenting does result in a greater degree of impairment of endothelial function and coronary vasodilatory reserve than balloon angioplasty [13][14][15], and these may cause distal particulate embolization from the targeted lesion, the release of vasoactive substances such as serotonin due to platelet activation, and increased inflammatory response at sites of stent implantation [16][17][18]. Such mechanisms have been attributed to the greater inflation pressures and vessel wall disruption associated with stent implantation.…”
Section: Discussionmentioning
confidence: 99%
“…Η δυαδική ανάλυση Έχουν προταθεί αρκετές εξηγήσεις για τις περιπτώσεις αναστρέψιμων προβλημάτων αιμάτωσης μετά την εμφύτευση stent, αλλά η κατάσταση εξακολουθεί να είναι ασαφής. Η στεφανιαία εισαγωγή stent έχει ως αποτέλεσμα μεγαλύτερο βαθμό δυσλειτουργίας της ενδοθηλιακής λειτουργίας και στεφανιαίας αγγειοδιασταλτικής ικανότητας από την αγγειοπλαστική με μπαλονάκι(Kern et al 1999), και αυτό μπορεί να προκαλέσει περιφερική εμβολή σωματιδίων από τη στοχευμένη περιοχή βλάβης, την απελευθέρωση αγγειοδραστικών ουσιών όπως η σεροτονίνη λόγω της ενεργοποίησης των αιμοπεταλίων και την αυξημένη φλεγμονώδη αντίδραση σε σημεία της εμφύτευσης stent(Marx et al 2006). Τέτοιοι μηχανισμοί έχουν αποδοθεί στις μεγαλύτερες πιέσεις και στη διαταραχή του τοιχώματος του αγγείου που σχετίζεται με την εμφύτευση stent.…”