1961
DOI: 10.1080/00028896109343395
|View full text |Cite
|
Sign up to set email alerts
|

Distribution and Excretion Studies in Dogs Exposed to an Aerosol Containing Polonium-210

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

1967
1967
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(15 citation statements)
references
References 4 publications
0
15
0
Order By: Relevance
“…The value of f r is lower, which might reflect a difference resulting from the method of administration, or a higher proportion of colloidal material in the inhalation experiment. The value of s r (rounded to 2 d −1 ) was therefore used in the analyses of results of other experiments with similar forms of polonium, but for which there were insufficient data to define s r . (547) Smith et al. (1961) determined the distribution of 210 Po at approximately 1, 4, and 5 months after inhalation by six dogs of polonium hydroxide colloid (neutralised 210 Po chloride) carried on a sodium chloride vector aerosol (count median diameter = 0.04 µm), similar to that inhaled by rats (Casarett, 1964).…”
Section: Polonium (Z = 84)mentioning
confidence: 99%
See 3 more Smart Citations
“…The value of f r is lower, which might reflect a difference resulting from the method of administration, or a higher proportion of colloidal material in the inhalation experiment. The value of s r (rounded to 2 d −1 ) was therefore used in the analyses of results of other experiments with similar forms of polonium, but for which there were insufficient data to define s r . (547) Smith et al. (1961) determined the distribution of 210 Po at approximately 1, 4, and 5 months after inhalation by six dogs of polonium hydroxide colloid (neutralised 210 Po chloride) carried on a sodium chloride vector aerosol (count median diameter = 0.04 µm), similar to that inhaled by rats (Casarett, 1964).…”
Section: Polonium (Z = 84)mentioning
confidence: 99%
“…(547) Smith et al. (1961) determined the distribution of 210 Po at approximately 1, 4, and 5 months after inhalation by six dogs of polonium hydroxide colloid (neutralised 210 Po chloride) carried on a sodium chloride vector aerosol (count median diameter = 0.04 µm), similar to that inhaled by rats (Casarett, 1964).…”
Section: Polonium (Z = 84)mentioning
confidence: 99%
See 2 more Smart Citations
“…A small number of dogs were exposed via inhalation to Po-210-chloride carried on a sodium-chloride aerosol, with a CMD of 0.04 μm (Smith et al 1961). Average respiratory tract deposition was reported to be 64 %, with values ranging from 48 -77 %, based on use of 6 dogs.…”
Section: Respiratory Tract Deposition Of Inhaled Po-210mentioning
confidence: 99%