“…The optical model code OPTMAN [39,40] was used for OMP parameter fitting. Originally the code did not include dispersion terms, so numerical [41] and analytical solutions [42,43] of dispersion relations were implemented within the OPTMAN code. We used symmetric surface and nonsymmetric volume imaginary absorptive potentials; therefore we initially adjusted 16 parameters, namely V 0 , λ HF , and C viso , which define the smooth energy dependence of the real volume potential; W 0 , C wiso , B s , C s and A v , B v , E a , which define the surface and volume absorptive potentials, respectively; and six geometrical parameters (r HF , a HF , r v , a v , r s , a s ).…”