2022
DOI: 10.1016/j.bios.2022.114570
|View full text |Cite
|
Sign up to set email alerts
|

Directly immersible silicon photonic probes: Application to rapid SARS-CoV-2 serological testing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 39 publications
0
7
0
Order By: Relevance
“…The immersible photonic sensors (US Patent 11,119,040; EPO Patent Application: EP3532825A1), their principle of operation, and the accompanying reader configuration have been described in detail in [34]. Briefly, the silicon-based photonic sensors were fabricated at the clean-room facility of the Nanotechnology and Microsystems Laboratory, Institute of Nanoscience and Nanotechnology, NCSR "Demokritos", on 4″ wafers with a 5 μm thick silicon dioxide bottom cladding layer and an LPCVD-grown silicon nitride layer (SiMat, Kaufering, Germany).…”
Section: Immersible Photonic Sensors and Readermentioning
confidence: 99%
See 3 more Smart Citations
“…The immersible photonic sensors (US Patent 11,119,040; EPO Patent Application: EP3532825A1), their principle of operation, and the accompanying reader configuration have been described in detail in [34]. Briefly, the silicon-based photonic sensors were fabricated at the clean-room facility of the Nanotechnology and Microsystems Laboratory, Institute of Nanoscience and Nanotechnology, NCSR "Demokritos", on 4″ wafers with a 5 μm thick silicon dioxide bottom cladding layer and an LPCVD-grown silicon nitride layer (SiMat, Kaufering, Germany).…”
Section: Immersible Photonic Sensors and Readermentioning
confidence: 99%
“…It employs a novel type of immersible Si-based photonic sensor using Broad-band Mach-Zehnder Interferometry (BB-MZIs) as the principle of operation [31][32][33]. The two most important novelties behind this type of sensor make it stand out and render it suitable for this study, as presented in detail in [34] and as will be further analyzed in Section 2.2: (1) Contrary to "traditional" biosensors, they do not require any microfluidics, but can be directly immersed into the analytes. This feature alleviates the need for tubes and pumps.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The possibility of integrating a broadband light source, a planar interferometer and a spectral spectrum detection system on one substrate was also shown [16]. Recently, a paper [17] was published in which a broadband Mach-Zehnder interferometer enabled the detection of SARS-CoV-2 antibodies.…”
Section: Introductionmentioning
confidence: 99%