2023
DOI: 10.3390/en16052087
|View full text |Cite
|
Sign up to set email alerts
|

Directions of Development of Diagnostic Methods of Vacuum Medium-Voltage Switchgear

Abstract: The development of power grid infrastructure and increasingly stringent environmental regulations have intensified work, carried out by researchers and electrical equipment manufacturers, to develop innovative gas-insulated, environmentally neutral devices. The emergence of new designs of circuit breakers and disconnectors, in which the resulting electric arc is extinguished in a vacuum environment, requires the development of appropriate techniques for diagnosing the chambers responsible for the dielectric pa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 105 publications
0
1
0
Order By: Relevance
“…The arc is finally extinguished at 5.8 ms. The proposed simulation method considers a nonlinear conductivity model of the sheath layer to better simulate the near-pole voltage drop and bending processes, which leads to more precise and truer current and voltage values compared to other works [10,11]. At the same time, the article simulated the actual product model, which was not achieved in previous articles because they only simulated an idealized model.…”
Section: Analysis Of Mcb Experimental Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The arc is finally extinguished at 5.8 ms. The proposed simulation method considers a nonlinear conductivity model of the sheath layer to better simulate the near-pole voltage drop and bending processes, which leads to more precise and truer current and voltage values compared to other works [10,11]. At the same time, the article simulated the actual product model, which was not achieved in previous articles because they only simulated an idealized model.…”
Section: Analysis Of Mcb Experimental Resultsmentioning
confidence: 99%
“…Zhao et al discuss the effects of arc ignition position, exhaust size, and gas-producing material on arc dynamics through an MHD model with a parallel pole-plate structure [10]. Pawel et al analyze the vacuum circuit breaker using the MHD method [11]. Rahimpour et al optimize the structure of solid-state circuit breaker using the MHD method [12].…”
Section: Introductionmentioning
confidence: 99%
“…In contrast to conventional oil switches and air switches, vacuum switches offer notable advantages such as a low failure rate and exceptional breaking performance. [1][2][3] Compared with SF 6 switches commonly utilized in high-voltage and ultrahigh-voltage power systems, vacuum switches boast the signicant advantage of emitting zero greenhouse gases. Regarded as the most ideal alternative to SF 6 switches, vacuum switches nd extensive use in mediumvoltage and high-voltage transmission power systems.…”
Section: Introductionmentioning
confidence: 99%
“…In order to avoid the use of non-environmentally friendly gases, an environmentally friendly alternative must gradually replace the greenhouse gas SF 6 as the insulating medium of the switchgear. At present, switching equipment insulated by vacuum or air and other environmentally friendly gases has become a hot research and development topic [1][2][3].…”
Section: Introductionmentioning
confidence: 99%