2014
DOI: 10.2341/12-464-l
|View full text |Cite
|
Sign up to set email alerts
|

Direct Spectrometry: A New Alternative for Measuring the Fluorescence of Composite Resins and Dental Tissues

Abstract: The aim of this study was to evaluate the fluorescence intensity of different composite resins and compare those values with the fluorescence intensity of dental tissues. Different composite resins were used to make 10 discs (2 mm in depth and 4 mm in diameter) of each brand, divided into groups: 1) Z (Filtek Z350, 3M ESPE), 2) ES (Esthet-X, Dentsply), 3) A (Amelogen Plus, Ultradent), 4) DVS (Durafill-VS, Heraeus Kulzer) with 2 mm composite resin for enamel (A2), 5) OES ([Esthet-X] opaque-OA [1 mm] + enamel-A2… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
26
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(27 citation statements)
references
References 20 publications
1
26
0
Order By: Relevance
“…The results showed that the CR Filtek Z350 obtained FI means closest to those of tooth, corroborating previous studies. 8,23 Esthet-X, Amelogen Plus, and Durafill VS showed higher intensity values than those of tooth, as observed by da Silva et al 23 It may be related to differences in fluorophore within the composition of each CR, trade secret not disclosed by the manufacturers. The differences in fluorescence values could be related to the difference in type of particles as well as resin matrix.…”
Section: Discussionsupporting
confidence: 57%
See 4 more Smart Citations
“…The results showed that the CR Filtek Z350 obtained FI means closest to those of tooth, corroborating previous studies. 8,23 Esthet-X, Amelogen Plus, and Durafill VS showed higher intensity values than those of tooth, as observed by da Silva et al 23 It may be related to differences in fluorophore within the composition of each CR, trade secret not disclosed by the manufacturers. The differences in fluorescence values could be related to the difference in type of particles as well as resin matrix.…”
Section: Discussionsupporting
confidence: 57%
“…24 However, little is known about the fluorophore agents present in the CRs, because it is a trade secret. 23,24 There is no fluorescence pattern to be followed, comparatively to which happen with the color scales. Most manufacturers follow the VITA color scale (A, B, C, and D).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations