2008
DOI: 10.1016/j.talanta.2008.04.014
|View full text |Cite
|
Sign up to set email alerts
|

Direct sample introduction of wines in graphite furnace atomic absorption spectrometry for the simultaneous determination of arsenic, cadmium, copper and lead content

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

4
58
1
2

Year Published

2009
2009
2016
2016

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 96 publications
(66 citation statements)
references
References 43 publications
4
58
1
2
Order By: Relevance
“…Therefore it is very significant to examine the trace levels of it in environments [2].Presently, the mostcommon analytical methods for the determination of trace amount of lead are the flame atomic absorption spectrometry (FAAS) [3]. The electrothermal atomic absorption spectrometry (ETAAS) [4]and the inductively coupled plasma emission spectrometry (ICP) [5]. Flame atomic absorption spectrometry is by far the most commonly employed technique for analyte determination [6].…”
Section: Introduction:-mentioning
confidence: 99%
“…Therefore it is very significant to examine the trace levels of it in environments [2].Presently, the mostcommon analytical methods for the determination of trace amount of lead are the flame atomic absorption spectrometry (FAAS) [3]. The electrothermal atomic absorption spectrometry (ETAAS) [4]and the inductively coupled plasma emission spectrometry (ICP) [5]. Flame atomic absorption spectrometry is by far the most commonly employed technique for analyte determination [6].…”
Section: Introduction:-mentioning
confidence: 99%
“…3 La aplicación de ET AAS en el análisis unielemental en muestras de orina ha sido ampliamente señalada, específicamente en la determinación de Cr, [4][5][11][12][13][14][15] y Ni. 7,14 Asimismo, se ha señalado el análisis multielemental en orina mediante ET AAS, en particular la determinación de cromo, 16,17 y niquel, 18,19 y otros elementos, 17,18,20 así como en otros tipos de muestras como particulado ambiental, 21 aleaciones de aluminio, 22 aguas y materiales geológicos, 23 miel, 24 y vino, 25 entre otras. Hasta donde se conoce, la determinación de V en orina mediante ET AAS no se ha señalado, empleándose en su lugar ICP-MS con espectrómetros de alta resolución (HR-ICP-MS), 10,26 con celdas de reacción dinámica, 8 y octopolos con celda de colisión, 9 así como la espectrometría de emisión atómica con plasma acoplado inductivamente (ICP OES) aplicando procedimientos previos de separación y preconcentración del elemento, para evitar las interferencias espectrales así como alcanzar los límites de detección requeridos.…”
Section: Introductionunclassified
“…According to a recent literature survey a wide variety of analytical techniques have been applied to quantify the trace metal content of wine, such as ion chromatography, stripping potentiometry, inductively coupled plasma mass spectrometry, inductively coupled plasma optical emission spectrometry, flame atomic absorption spectrometry, and electrothermal atomic absorption spectrometry (ET AAS). 10,11 Sample pretreatment is usually required for achieving good accuracy and to destroy the organic matrix and/or to extract the metal ions bound in inorganic and organic complexes. 12 Besides this, cadmium is present in wine at low concentration and its determination in this kind of sample requires the use of analytical techniques of high sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…In this context, ET AAS is a good choice, because of its good detectivity and its tolerance of inorganic and organic matrices, which should make the direct determination of cadmium in wine without any sample preparation possible. 11,13,14 Chemometric techniques have been applied in analytical chemistry for evaluation of results and also for optimization of analytical methods. [15][16][17][18][19] For evaluation, the multivariate analysis techniques: principal component analysis (PCA) and hierarchical cluster analysis (HCA) are the ones that are employed most frequently.…”
Section: Introductionmentioning
confidence: 99%