2020
DOI: 10.1055/s-0040-1721529
|View full text |Cite
|
Sign up to set email alerts
|

Direct Percutaneous Puncture and Embolization of Visceral Pseudoaneurysm: Safety and Clinical Efficacy

Abstract: Purpose The aim of the study is to assess the safety and clinical effectiveness of direct percutaneous embolization of visceral artery pseudoaneurysms. Materials and Methods Retrospective analysis of patients who had undergone direct percutaneous embolization of visceral artery pseudoaneurysms between January 2012 and May 2017 was performed. The study included 26 patients with a mean age of 36 years (range 10–71 years). The indications for direct percutaneous embolization included the inability to catheterize … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 22 publications
0
2
0
Order By: Relevance
“…Rupture of an aneurysm or pseudoaneurysm during direct puncture embolization is a concern, but no such ruptures had been reported in the literature. [3][4][5]7,9,10 Slow blood aspiration through the puncture needle and gradual coil packing during embolization are likely to lower the risk of rupture because of a decrease in intra-aneurysmal pressure. In each of our five patients, we used a 21-or 18-gauge puncture needle and no aneurysmal rupture during the procedures.…”
Section: J Chin Med Assocmentioning
confidence: 99%
See 1 more Smart Citation
“…Rupture of an aneurysm or pseudoaneurysm during direct puncture embolization is a concern, but no such ruptures had been reported in the literature. [3][4][5]7,9,10 Slow blood aspiration through the puncture needle and gradual coil packing during embolization are likely to lower the risk of rupture because of a decrease in intra-aneurysmal pressure. In each of our five patients, we used a 21-or 18-gauge puncture needle and no aneurysmal rupture during the procedures.…”
Section: J Chin Med Assocmentioning
confidence: 99%
“…According to the flow dynamics inside an aneurysm and the risk of nontarget embolization, the ratio of NBCA to lipiodol is typically 1:1 to 1:3. 6,[9][10][11]13,19,22 As this ratio increases, the polymerization time is prolonged, possibly increasing the risk of nontarget embolization. To prevent glue spillage and to protect other vessels from nontarget embolization, an intravascular balloon can be inflated during the procedure.…”
Section: J Chin Med Assocmentioning
confidence: 99%