2020
DOI: 10.1021/acs.energyfuels.0c01810
|View full text |Cite
|
Sign up to set email alerts
|

Direct Mass Spectrometric Analysis of Solid Coal Samples Using Laser Desorption/Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Abstract: The direct analysis of complex organic solid samples, such as coal, still represents a challenge for mass spectrometric researchers. In this work, we present an approach to analyze various carbonaceous samples with different degrees of coalification (one peat and five coals) using laser desorption/ionization in negative ion mode (LDI(−)) and ultrahigh resolving Fourier transform ion cyclotron resonance mass spectrometry. This preparation and analysis method enables a characterization of reactive organic molecu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(17 citation statements)
references
References 78 publications
(115 reference statements)
0
17
0
Order By: Relevance
“…536 It may resolve the ionized analytes according to their individual cyclotron frequencies, which are inversely related to the mass-to-charge ratios (m/z) of the analyte ions. 37 FT-ICR-MS can be utilized for very high-boiling and non-boiling petroleum fractions beyond the reach of GC/GC × GC through direct insertion or infusion. FT-ICR measures the motion of ion orbiting trapped in a magnetic field of an analyzer cell.…”
Section: Liquid Chromatography Coupled To Mass Spectrometry (Lc-ms)mentioning
confidence: 99%
See 3 more Smart Citations
“…536 It may resolve the ionized analytes according to their individual cyclotron frequencies, which are inversely related to the mass-to-charge ratios (m/z) of the analyte ions. 37 FT-ICR-MS can be utilized for very high-boiling and non-boiling petroleum fractions beyond the reach of GC/GC × GC through direct insertion or infusion. FT-ICR measures the motion of ion orbiting trapped in a magnetic field of an analyzer cell.…”
Section: Liquid Chromatography Coupled To Mass Spectrometry (Lc-ms)mentioning
confidence: 99%
“…592,593 It is known that direct ionization sources may exhibit drawbacks in comparison to classical ionization methods such as ESI, due to pronounced signal suppression and low detection selectivity. 37 Therefore, coupling LDI source with FT-ICR-MS seems to have a high potential for direct analysis of the volatile and reactive part of a complex solid sample. LDI-FT-ICR-MS 73,[594][595][596] can offer a higher mass resolution, mass resolving power, and mass accuracy, enabling the analysis of complex petroleum mixtures on a molecular level.…”
Section: Laser Desorption/ionization (Ldi)mentioning
confidence: 99%
See 2 more Smart Citations
“…This study served as a proof-of-principle that high quality analysis of NOM samples can be performed with minimal sample preparation and miniscule sample amount (several μg), nevertheless affording the same level of sensitivity and accuracy as specially prepared samples used with other ionization techniques. LI analysis of several coal samples has demonstrated a correlation between the mass spectral data and the degree of coalification using several different types of data evaluation methods (Zuber et al, 2020).…”
Section: Use Of Lims In Analysis Of Organic and Biological Samplesmentioning
confidence: 99%