2010
DOI: 10.1109/tpwrs.2009.2038920
|View full text |Cite
|
Sign up to set email alerts
|

Direct Load Control (DLC) Considering Nodal Interrupted Energy Assessment Rate (NIEAR) in Restructured Power Systems

Abstract: A direct load control (DLC) scheme of air conditioning loads (ACL) considering direct monetary compensation to ACL customers for the service interruption caused by the DLC program is proposed in this paper for restructured power systems. The nodal interrupted energy assessment rate (NIEAR), which is used as the bids from the ACL customers, is utilized to determine the direct monetary compensation to the ACL customers. The proposed scheme was investigated for the PoolCo electricity market. The optimal DLC schem… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 40 publications
(8 citation statements)
references
References 22 publications
0
7
0
Order By: Relevance
“…These programs mostly target smaller loads that cannot provide sophisticated and expensive communication and monitoring infrastructure. This business model is suitable for smaller loads with flexibility in their electrical appliances that can be aggregated in large numbers, such as thermostatically controlled loads, air conditioners, refrigerators, and pool pumps [29,30]. Aggregation techniques in this business model are very important to minimize the loss of welfare of DR resources [31].…”
Section: Contract-based Reliability Enhancing Servicementioning
confidence: 99%
“…These programs mostly target smaller loads that cannot provide sophisticated and expensive communication and monitoring infrastructure. This business model is suitable for smaller loads with flexibility in their electrical appliances that can be aggregated in large numbers, such as thermostatically controlled loads, air conditioners, refrigerators, and pool pumps [29,30]. Aggregation techniques in this business model are very important to minimize the loss of welfare of DR resources [31].…”
Section: Contract-based Reliability Enhancing Servicementioning
confidence: 99%
“…IBPs reward those customers who participate in the programs with a credit bill or a discount rate. Direct load control programs allow utilities to shut down contracting equipment on short notice [38]. Programs that can be curtailed encourage participants to reduce their loads to a predefined value; otherwise, extra penalties will be charged [39].…”
Section: Demand Response (Dr) Of Phevs/evsmentioning
confidence: 99%
“…A load direct control (LDC) to disconnect strategic loads belonging to users is proposed in [10]. The authors propose a stochastic optimization model to reduce the total cost of operation, based on the efficient use of traditional and renewable sources of energy.…”
Section: Introductionmentioning
confidence: 99%