2017
DOI: 10.1049/el.2017.1772
|View full text |Cite
|
Sign up to set email alerts
|

Direct flux control – sensorless control method of PMSM for all speeds – basics and constraints

Abstract: This document is the author's post-print version, incorporating any revisions agreed during the peer-review process. Some differences between the published version and this version may remain and you are advised to consult the published version if you wish to cite from it.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 7 publications
0
5
0
Order By: Relevance
“…So, the rotor position of the PMSM drive is estimated using stator voltage, current, and flux quantity of PMSM drive. In PMSM drive, the rotor position can be determined by flux linkage sensing [17], position dependence of inductances [18], current slope detection [19], zerocrossing back EMF, state observer-based [20], etc.…”
Section: Imentioning
confidence: 99%
See 1 more Smart Citation
“…So, the rotor position of the PMSM drive is estimated using stator voltage, current, and flux quantity of PMSM drive. In PMSM drive, the rotor position can be determined by flux linkage sensing [17], position dependence of inductances [18], current slope detection [19], zerocrossing back EMF, state observer-based [20], etc.…”
Section: Imentioning
confidence: 99%
“…T. Muller et al [17] presents a flux linkage sensing method to estimate the rotor and speed position of the PMSM drive. This method is dependent on the motor phase voltage equation.…”
Section: Imentioning
confidence: 99%
“…However, other methods that exploit the saliency of the AC machine exist, and they have been not so extensively studied as the high-frequency injection methods. The latter is the case of the INFORM method [21,22] and the Direct Flux Control (DFC) method [23,24]. Although both methods send pulsating voltage signals to the machine in order to obtain the rotor position, the difference lies in the output signal used for the rotor position estimation.…”
Section: Introductionmentioning
confidence: 99%
“…In recent research studies, the flux control method has been proposed to overcome such latency in protection system performance in the case of connecting large-scale steam units to the power system [5]. However, since this method reduces the active output power of the generator, it can potentially lead to transient system instability due to the imbalance between generation and consumption.…”
Section: Introductionmentioning
confidence: 99%