1985
DOI: 10.1002/anie.198500481
|View full text |Cite
|
Sign up to set email alerts
|

Direct Enantiomer Resolution of Hydroxy and Carbonyl Compounds by Gas Chromatography on Chirasil‐Val

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
1

Year Published

1988
1988
1998
1998

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(9 citation statements)
references
References 19 publications
0
8
0
1
Order By: Relevance
“…Although these conclusions derive from experiments on a tripodal trispeptide selector, we trust that they are of relevance also to single- stranded diamide phases, because the behavior of the tripodal selector and diamide selectors (i.e., Chirasil-Val) is analogous in terms of separation factor ratios and elution orders. [6][7][8] The findings represented here on the involvement of hydrogen bonds in selector-solute interactions are believed to contribute to the future development of superior chiral phases.…”
Section: Discussionmentioning
confidence: 92%
See 2 more Smart Citations
“…Although these conclusions derive from experiments on a tripodal trispeptide selector, we trust that they are of relevance also to single- stranded diamide phases, because the behavior of the tripodal selector and diamide selectors (i.e., Chirasil-Val) is analogous in terms of separation factor ratios and elution orders. [6][7][8] The findings represented here on the involvement of hydrogen bonds in selector-solute interactions are believed to contribute to the future development of superior chiral phases.…”
Section: Discussionmentioning
confidence: 92%
“…8,16 Although extensive investigations on the resolution mechanism of Chirasil-Val were performed, including thermodynamic analysis of retention data as well as conformational analysis of both solute and selector, 17-19 a reliable model for the resolution of racemic amino acids on Chirasil-Val 20 and on other diamide phases is still lacking. One of the difficulties is the lack of detailed structural information on the diamide selectors commonly used.…”
Section: -13mentioning
confidence: 99%
See 1 more Smart Citation
“…Gas chromatography was performed on a Perkin-Elmer Model Sigma 1 and a Carlo-Erba Model 2001 AC gas chromatograph. Samples of N-trifluoroacetyl amino acid isopropyl esters were eluted from a 26 m, 0.25 mm i.d., df = 0.3 µ , glass capillary column coated with L-Chirasil-Val (15,16). Samples of alcohols were eluted on a 33 m, 0.25 mm i.d., homemade glass capillary column coated with immobilized methylethenylpolysiloxane (17).…”
Section: Methodsmentioning
confidence: 99%
“…Esta columna permitió la separación de todos los aminoácidos proteínicos racémicos en un cromatograma tomando sólo 30 minutos [27]. La columna Chirasil-Val fue usada para separar muchas otras mezclas quirales incluyendo los arilglicoles, metabolitos de fármacos, ácidos 2-y 3-hidroxicarboxílicos [28] y muchas sustancias no derivadas como los alcoholes, dicetonas e hidroxi lactonas [29].…”
Section: Figura 14 Estructura Del Polisiloxano L-valina-tert-butilaunclassified