BATH/ASME 2018 Symposium on Fluid Power and Motion Control 2018
DOI: 10.1115/fpmc2018-8812
|View full text |Cite
|
Sign up to set email alerts
|

Direct Driven Pump Control of Hydraulic Cylinder for Rapid Vertical Position Control of Heavy Loads: Energy Efficiency Including Effects of Damping and Load Compensation

Abstract: The ever-tightening government-enforced regulations for more energy efficient and less polluting machines and the simultaneous fast development of electric drives have caused hydraulic systems to lose ground to electric drives. One promising solution to improve the status of hydraulics in this competition are the Direct Driven Hydraulic (DDH) systems, aka electro-hydraulic actuators (EHAs), which are characterized by a closed circuit type and a servo motor driven speed-controlled pump controlling the actuator.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…With the P-controller, it has previously been possible to achieve a rise time of approximately one second [26,27]. In these tests, as well as in the tests of the current study, the P-controller's task was facilitated by using a rate limiter, which replaced the step-wise change in the position reference with a steep ramp.…”
Section: Discussionmentioning
confidence: 91%
See 4 more Smart Citations
“…With the P-controller, it has previously been possible to achieve a rise time of approximately one second [26,27]. In these tests, as well as in the tests of the current study, the P-controller's task was facilitated by using a rate limiter, which replaced the step-wise change in the position reference with a steep ramp.…”
Section: Discussionmentioning
confidence: 91%
“…In addition, the motion was plagued with a series of pressure spikes causing unwanted fluctuations in the linear velocity of the actuator piston during the stroke. In tests where load compensation was not used, the pressure spikes in the lifting chamber of the actuator cylinder could exceed 200 bar [26,27]. The problems with motion vibrations and high chamber pressures became even more pronounced when the rise time was shortened below one second.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations