1974
DOI: 10.1021/ac60345a014
|View full text |Cite
|
Sign up to set email alerts
|

Direct determination of trace quantities of lead, bismuth, selenium, tellurium, and thallium in high temperature alloys by nonflame atomic absorption spectrophotometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
5
0

Year Published

1975
1975
2000
2000

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 54 publications
(6 citation statements)
references
References 7 publications
(1 reference statement)
1
5
0
Order By: Relevance
“…The tellurium results compare well with the only previously reported atmospheric measurement of <0.8 ng/m3 in College Park, Md. (19).…”
Section: Resultssupporting
confidence: 89%
See 1 more Smart Citation
“…The tellurium results compare well with the only previously reported atmospheric measurement of <0.8 ng/m3 in College Park, Md. (19).…”
Section: Resultssupporting
confidence: 89%
“…Atomic absorption spectrometry has been utilized to determine tellurium, generally above the /xg/g concentration level (18,19), but again this technique does not have the sensitivity necessary to determine tellurium in most biological and environmental matricies without a pre-concentration step.…”
mentioning
confidence: 99%
“…The analysis of this alloy for trace metals using atomic absorption, without resorting to time consuming extraction procedures (20), is difficult because of a large amount of spectral background interference. This interference is caused by scattering, by molecular absorption, and by atomic absorption of matrix elements (21,22). Using LEI, a determination of In in this sample was performed.…”
Section: Methodsmentioning
confidence: 99%
“…More complete wavelength tables (12)(13)(14) show that most analytically useful resonance lines fall quite close to numerous lines from many commonly encoutered elements. The presence of these lines must be taken into account when attempting trace AA analysis in complex matrices (6,15). CEWMAA is much less susceptible to this type of spectral interference since the very high resolution of the echelle monochromator eliminates all non-analyte absorbing lines from the spectral bandwidth, except those which result in direct absorption spectral overlap.…”
Section: Discussionmentioning
confidence: 99%
“…This critical pH adjustment requires some practice and is time consuming, but the fuming with H2S04 has the advantage of preventing premature hydrolysis of the actinides. Puphal and Olsen (15) prevented the hydrolysis of actinides before the electrodeposition by fuming the sample…”
mentioning
confidence: 99%