2004
DOI: 10.1016/j.ab.2004.04.005
|View full text |Cite
|
Sign up to set email alerts
|

Direct determination of phosphate in urine by sequential-injection analysis with single on-line dilution–calibration method and photometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
3
0

Year Published

2005
2005
2012
2012

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(4 citation statements)
references
References 19 publications
1
3
0
Order By: Relevance
“…The mass of 234.81 u corresponds relatively well with the mass of 139 LaHPO 4 1 (234.89 u). In a study by Themelis et al, 13 the concentration of phosphate in urine varied between 0.9 and 1.5 g l À1 , which is in accordance with the concentrations used in this study. According to Minoia et al, 14 the concentration of La in urine can be expected to vary between 0.015 and 3.6 mg l À1 .…”
Section: Interference Pattern From Various Lanthanidessupporting
confidence: 90%
“…The mass of 234.81 u corresponds relatively well with the mass of 139 LaHPO 4 1 (234.89 u). In a study by Themelis et al, 13 the concentration of phosphate in urine varied between 0.9 and 1.5 g l À1 , which is in accordance with the concentrations used in this study. According to Minoia et al, 14 the concentration of La in urine can be expected to vary between 0.015 and 3.6 mg l À1 .…”
Section: Interference Pattern From Various Lanthanidessupporting
confidence: 90%
“…SIA methods have recognised merits of robustness and versatility enabling the possibility to change the determination conditions without physical reconfiguration of the manifolds. In this scenario, several SIA methods have been reported for the spectrophotometric determination of phosphate [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20] as listed in Table 1. However, these methods were generally developed for the application to a single type of water (even when other samples were also used).…”
Section: Introductionmentioning
confidence: 99%
“…Automation of sample dilution using sequential injection analysis (SI) offers significant possibilities and advantages over batch or previously applied on-line dilution protocols. On-line dilution can be carried out by zone sampling in a practically single-channelled operation mode [9], without reconfigura-tion of the manifolds by adding extra dilution lines [10], dialysis units [11] or mixing chambers [12].…”
Section: Introductionmentioning
confidence: 99%